Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo


Product Detail

Related Video

Feedback (2)

To become the stage of realizing dreams of our employees! To build a happier, much more united and far more professional team! To reach a mutual profit of our clients, suppliers, the society and ourselves for Chromogenic endotoxin assay, 1000ul Pipette tip box, Endotoxin Assay Kits, We hope to establish more business relationships with customers all over the world.
Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate (LAL) Multi-test Vial, G17 series

 

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which choose gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 1.7ml per vial.

2. Product Parameter

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, water for injection endotoxin assay, raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.  

Note: Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.  

 

Gel clot method LAL assay, reconstituted lysate reagent get at least 16 tests per vial:

Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G170030 0.03 1.7 16 10
G170060 0.06 1.7 16 10
G170125 0.125 1.7 16 10
G170250 0.25 1.7 16 10
G170500 0.5 1.7 16 10

Product condition: The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis.  

 

Why the most microbiologists to select gel clot assay kit G17 series ? 

1.  LAL reagent G17 series is the most universal method to show the presence of endotoxins based on if gel formation in the sample tube when operate the bacterial endotoxin test.

2. Multi limulus lysate test for endotoxin detection in the parenteral drugs, when detect the moderate quantity samples.

3. LAL test procedure of incubation, the convenient device is water bath or dry heat incubator.

4. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tip (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.  

 

Related products in the endotoxin test assay:

  1. Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
  2. Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
  3. Pyrogen free tips,  Recommend PT25096 or PT100096
  4. Pipettor, Recommend PSB0220
  5. Test Tube Rack
  6. Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
  7. Vortex Mixter, Recommend VXH.
  8. Control Standard Endotoxin, CSE10V.

 

Bioendo LAL test for pyrogens or LAL assay endotoxin, and TAL test, all descriptions are belong to the endotoxin test. 

Base on Bioendo processing art, the kits are lyophilized amebocyte lysate (LAL).

Below words original From Wikipedia, the free encyclopedia

Limulus amebocyte lysate (LAL) is an aqueous extract of blood cells (amoebocytes) from the Atlantic horseshoe crab Limulus polyphemus. LAL reacts with bacterial endotoxin lipopolysaccharide (LPS), which is a membrane component of gram-negative bacteria. This reaction is the basis of the LAL test, which is widely used for the detection and quantification of bacterial endotoxins.

In Asia, a similar Tachypleus amebocyte lysate (TAL) test based on the local horseshoe crabs Tachypleus gigas or Tachypleus tridentatus is occasionally used instead. The recombinant factor C (rFC) assay is a replacement of LAL/TAL based on a similar reaction.

 


Product detail pictures:

Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures

Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo detail pictures


Related Product Guide:

We thinks what buyers think, the urgency of urgency to act during the interests of a purchaser position of theory, allowing for much better high-quality, reduced processing costs, charges are more reasonable, won the new and outdated consumers the support and affirmation for Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo , The product will supply to all over the world, such as: Australia, Georgia, Hungary, We have many years' experience in hair product production, and our strict QC Team and skilled workers will ensure that we give you top hair products with the best hair quality and workmanship. You will get successful business if you choose to cooperate with such a professional manufacturer. Welcome your order cooperation!
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Edith from Afghanistan - 2018.05.15 10:52
    The sales manager has a good English level and skilled professional knowledge, we have a good communication. He is a warm and cheerful man, we have a pleasant cooperation and we became very good friends in private.
    5 Stars By Eudora from Sudan - 2018.09.19 18:37

    Leave Your Messages

    Related products

    • Professional China bacterial endotoxin test - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Professional China bacterial endotoxin test - ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo

      OEM/ODM China Bacterial Endotoxin Test Gel Clot...

      Bioendo GC Endotoxin Test Kit Bioendo GC Endotoxin Test Kit (Gel Clot Assay)  1. Product Information Bioendo GC Endotoxin Test Kit (Gel Clot Assay) contains 128 Tests/Kit, 400Tests/Kit, 1600Tests/Kit, and 4500 Tests/Kit. And sensitivity of Amebocyte Lysate included by the Kit is 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Kit contains Amebocyte Lysate, CSE and Water for BET. Four kinds of configuration of gel-clot endotoxin assay kit to satisfied the demand. This means yo...

    • New Arrival China Kinetic Turbidimetric Method endotoxin - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      New Arrival China Kinetic Turbidimetric Method ...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • OEM Manufacturer BET Test Procedure - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM Manufacturer BET Test Procedure - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • 2022 China New Design LAL test for endotoxin - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      2022 China New Design LAL test for endotoxin -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Trending Products Bacterial Endotoxin Test For Water For Injection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Trending Products Bacterial Endotoxin Test For ...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...