Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo


Product Detail

Related Video

Feedback (2)

"Control the quality by the details, show the strength by quality". Our company has strived to establish a highly efficient and stable staff team and explored an effective quality control process for LAL endotoxin kit, 1000ul Pipette tip box, Chromogenic Endotoxin Testing, In case you pursuit the Hi-quality, Hi-stable, Aggressive price elements, corporation name is your greatest choice!
Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo Detail:

LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water ) 

1. Product Information

LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could be used to dilute the assay sample, construct the stand curve, or reconstitute the Lyophilized Amebocyte Lysate reagents. 

2. Product Parameter

Endotoxin level: ≤0.005 EU/ml

Water for Bacterial Endotoxins Test is specially processed water is used for endotoxin detection. Its endotoxin concentration is less than 0.005EU/ml. We also provide water for BET with endotoxin level less than 0.001EU/ml for the assay sensitivity 0.001 to 5EU/ml kinetic chromogenic assay.

 

3. Product Features and Application

Endotoxin Free Water (Water for BET, LAL Reagent water, Endotoxin free water or BET water) is specially processed water intended for reconstitution of Lyophilized Amebocyte Lysate and Control Standard Endotoxin (CSE), and to dilute samples and control standards in the endotoxin assay operation.

For reconstitution of Lyophilized Amebocyte Lysate or Amebocyte Lysate, dilution of the test samples and Control Standard Endotoxin, preparation endotoxin free buffers, and construction of the standard curve. 500ml BET water main apply in extract endotoxins from medical devices. 

Catalog No.

Volume (ml/vial)

Package

TRW02

2ml in Ampoule

In Ampoule, 10 Ampoules/Pack

TRW05

5ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW10

10ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW50

50ml in Glass Vial

In Glass Vial, 10 Vials/Pack

TRW100

100ml in Glass Vial

 In Glass Vial, 10 Vials/Pack

TRW500

500ml in Glass Bottle

1 Vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

What is BET water (bacterial endotoxin test water)?

Bacterial endotoxin test water that is endotoxin free level water, it mainly use for endotoxin test assay in the operation of reconstitution and dilution.

Such as, reconstitute lyophilized lysate reagent, control standard endotoxin dilution reconstitution and dilution, and samples dilutions.

Bioendo BET water (Water for BET) can be named TAL reagent water or LAL reagent water. LAL (lyophilized amebocyte lysate).


Product detail pictures:

Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures


Related Product Guide:

The customer satisfaction is our primary goal. We uphold a consistent level of professionalism, quality, credibility and service for Reliable Supplier Endotoxin Detection Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo , The product will supply to all over the world, such as: Birmingham, Bahrain, Colombia, We will not only continuously introduce technical guidance of experts from both home and abroad, but also develop the new and advanced products constantly to satisfactorily meet the needs of our clients all over the world.
  • The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Annie from Hongkong - 2017.05.02 11:33
    This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Kim from Nigeria - 2018.08.12 12:27

    Leave Your Messages

    Related products

    • High Quality LAL Reagent - Vortex Mixer – Bioendo

      High Quality LAL Reagent - Vortex Mixer –...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Lowest Price for Bacteria That Produce Endotoxins - Control Standard Endotoxin (CSE) – Bioendo

      Lowest Price for Bacteria That Produce Endotoxi...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • OEM Manufacturer BET Test Procedure - Nymph X Water Purification System – Bioendo

      OEM Manufacturer BET Test Procedure - Nymph X ...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Factory made hot-sale Bacterial Endotoxin Test Validation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory made hot-sale Bacterial Endotoxin Test ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • China Factory for Endotoxin Analysis Methods - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      China Factory for Endotoxin Analysis Methods -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Reasonable price Depyrogenated tips - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      Reasonable price Depyrogenated tips - Kinetic ...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...