Our workforce through professional training. Skilled professional knowledge, solid sense of service, to fulfill the services demands of consumers for Bacterial Endotoxin Test Failure Investigation, Define LAL Test, Endotoxin Gel Clot Test Kit, Welcome all nice buyers communicate details of solutions and ideas with us!!
OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

During the past few years, our business absorbed and digested state-of-the-art technologies the two at home and abroad. Meanwhile, our firm staffs a group of experts devoted to your development of OEM/ODM Manufacturer Endotoksin Testi - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Iceland, Ireland, Borussia Dortmund, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to in your case of fantastic good quality. Guided by the principle of "Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We have been confident that we've been going to have a bright prospect and to be distributed all over the world in the years to come.
  • The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Antonia from Accra - 2018.09.21 11:44
    This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Ellen from Congo - 2017.12.31 14:53

    Leave Your Messages

    Related products

    • Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory Cheap Hot limulus amebocyte lysate kit ...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Chinese Professional endotoxin removal - EtEraser™ HP Endotoxin Removal Kit – Bioendo

      Chinese Professional endotoxin removal - EtEra...

      EtEraser™ SE Endotoxin Removal Kit 1. Product information We are the expert of endotoxin testing and endotoxinremoval. We offer the complete solutions covering the whole range of endotoxincontrol, endotoxin monitoring and testing. Our products include laboratoryresearch uses endotoxin removal kits and could be scaled up to industrialproduction scale columns. Lipopolysaccharide (LPS) is a bacterial endotoxin anda major constituent of the cell walls of gram-negative bacteria. Recombinantprote...

    • Manufacturing Companies for Advantages Of LAL Test - Rapid Gel Clot 10 Samples Kit – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Chinese wholesale LAL test kit - Mini Dry Heat Incubator – Bioendo

      Chinese wholesale LAL test kit - Mini Dry Heat...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • High definition LAL Turbidimetric detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      High definition LAL Turbidimetric detection - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Hot New Products Rapid Gel Clot Endotoxin Test Kit For Water And Dialysate - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Hot New Products Rapid Gel Clot Endotoxin Test ...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...