OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

Our products are broadly identified and trustworthy by people and may meet continually modifying financial and social requires of Chromogenic LAL assay, Kinetic chromogenic TAL Assay, Endotoxin free tip box, We welcome all of the purchasers and pals to contact us for mutual added benefits. Hope to do additional business enterprise along with you.
OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

Well-run devices, expert profits group, and better after-sales companies; We have been also a unified huge family, everybody keep on with the organization worth "unification, determination, tolerance" for OEM Manufacturer BET Test Procedure - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Germany, USA, Angola, We'd like to invite customers from abroad to discuss business with us. We can present our clients with high quality products and excellent service. We're sure that we'll have good cooperative relationships and make a brilliant future for both parties.
  • Product variety is complete, good quality and inexpensive, the delivery is fast and transport is security, very good, we are happy to cooperate with a reputable company!
    5 Stars By Hilary from United Kingdom - 2017.06.22 12:49
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Martha from Slovakia - 2018.12.22 12:52

    Leave Your Messages

    Related products

    • Good Quality Kinetic Turbidimetric vs Kinetic Chromogenic - Endpoint Chromogenic Kit EC64405 – Bioendo

      Good Quality Kinetic Turbidimetric vs Kinetic C...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Lowest Price for Bacteria That Produce Endotoxins - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Lowest Price for Bacteria That Produce Endotoxi...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • 2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      2022 High quality LAL gel clot test - Gel Clot...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

    • Manufacturer for LAL endotoxin kit - Endotoxin-free Glass Test Tubes – Bioendo

      Manufacturer for LAL endotoxin kit - Endotoxin...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • 8 Year Exporter Endotoxin LAL Test - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      8 Year Exporter Endotoxin LAL Test - Endotoxin...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • New Arrival China Endpoint Chromogenic Endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      New Arrival China Endpoint Chromogenic Endotoxi...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...