Our business aims to operating faithfully, serving to all of our clients , and working in new technology and new machine continuously for Pipette tip supplier, Bacterial Endotoxin Calculation, Endotoxin LAL Method, Welcome you to join us together to make your business easier. We are always your best partner when you want to have your own business.
Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

It can be our duty to satisfy your preferences and successfully serve you. Your pleasure is our best reward. We have been looking forward to the go to for joint expansion for Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: San Diego, Argentina, Malta, Our solutions are widely recognized and trusted by users and can meet continuously changing of economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Joanne from Dominica - 2018.09.12 17:18
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Gustave from Haiti - 2017.11.11 11:41

    Leave Your Messages

    Related products

    • Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo

      Manufacturer for LAL reagent manufacturer - Ra...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Hot New Products LAL reagent sensitivity - Rapid Gel Clot single test kit – Bioendo

      Hot New Products LAL reagent sensitivity - Rap...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Popular Design for Endotoxin Indicator For Depyrogenation - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Popular Design for Endotoxin Indicator For Depy...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Wholesale Price Endotoxin challenge vial - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Wholesale Price Endotoxin challenge vial - End...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Online Exporter Endotoxin Detection System - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Online Exporter Endotoxin Detection System - B...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...