The organization keeps on the procedure concept "scientific management, high quality and efficiency primacy, purchaser supreme for Endotixins, BET Test Procedure, LAL testing medical devices, Quality is factory's life , Focus on customers' demand is the source of company survival and development, We adhere to honesty and good faith working attitude, looking forward to your coming !
Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo Detail:

Dry heat incubator single module

1. Product information

 The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation.

2. Product features

1. Unique designed. Smart and light, convenient movement, suit for various occasions.
2. LCD simultaneously display setting and actual time and  temperature.Temperature calibration function.
3. Automatic fault detection function with buzzer alarm.
4. 24V DC input power, built-in over-temperature protection device.
5. Various of blocks for optional choice. Convenient for replacement. Easy cleaning and disinfection.

Mini Dry Heat Incubator

Product detail pictures:

Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo detail pictures

Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo detail pictures

Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

Being supported by an highly developed and specialist IT team, we could give technical support on pre-sales & after-sales service for Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Georgia, Argentina, Russia, Corporate goal: Customers' satisfaction is our goal, and sincerely hope to establish long-terms stable cooperative relations with customers to jointly develop the market. Building brilliant tomorrow together!Our company regards "reasonable prices, efficient production time and good after-sales service" as our tenet. We hope to cooperate with more customers for mutual development and benefits. We welcome potential buyers to contact us.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Janet from Belarus - 2018.05.22 12:13
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Chloe from Guyana - 2017.12.09 14:01

    Leave Your Messages

    Related products

    • Factory directly Endotoxin Free Test Tubes - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Factory directly Endotoxin Free Test Tubes - P...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Manufacturing Companies for Advantages Of LAL Test - Rapid Gel Clot 10 Samples Kit – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Manufacturer of Dry Heat Sterilization Validation – Compact Modular Dry Heat Incubator – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • Wholesale Price China Kinetic Turbidimetric LAL kit for endotoxin detection - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Price China Kinetic Turbidimetric LAL...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Manufacturer for Kinetic chromogenic TAL Assay - Endpoint Chromogenic Kit EC64405 – Bioendo

      Manufacturer for Kinetic chromogenic TAL Assay ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Fast delivery 1000ul Pipette tip - Nymph X Water Purification System – Bioendo

      Fast delivery 1000ul Pipette tip - Nymph X Wat...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...