PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo


Product Detail

Related Video

Feedback (2)

Bear "Customer first, Excellent first" in mind, we operate closely with our customers and supply them with efficient and expert services for Bacterial Endotoxin Test Validation, Bacterial Endotoxin Calculation, BET Water, Our products are strictly inspected before exporting , So we gain a good reputation all over the world. We looking forward to cooperation with you in the future.
PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo Detail:

Kinetic Incubating Microplate Reader

1. Product information

Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be scaled up toautomatic performance.

2. Instrument parameters

- wavelength range of 340-900 nm, suitable for ultraviolet and visible light detection.

- 6 filter wheel, standard configuration with 5 filters (340,405, 490, 540 and 630 nm).

- temperature control range: room temperature+5℃ to 50℃

- standard curve linear correlation coefficient: |r|≥0.99

- assay repeatability: CV≤5%

- 96 tests per plate

3.  Application range:

- Bacterial endotoxin (pyrogen) assay of drugs, vaccines, Water for Injection medical devices, infusion, transfusion related devices dialysate,dialysis water endotoxin testing cell suspension, cell culture media, cell culture related products recombinant protein, nucleic acid and other molecular biological products

-Endotoxin level monitoring during production: pharmaceutical raw materials, intermediate products, end product endotoxin daily monitoring.

-Clinical diagnostic of sepsis and invasive fungi disease:plasma, serum, urine, cerebrospinal fluid endotoxin and (1,3)-beta-D-glucandetection.

Catalog No.

Description

KPR808IULAL

Kinetic incubating microplate reader Elx808  for Endotoxin and ß-glucan detection

20180903103214_47978

Please contact sales@houshiji.com to order the LAL reagents endotoxin detection kit.

There is no minimal order volume required.

The price depends on the order quantity. We provide distributor discount for our partners.

Bioendo provide professional transport services for sophisticated instruments to make sure safety international transportation.

 

Kinetic microplate incubating reader +

Quantitative Lysate reagent +

Pyrogen free microplate +

Pyrogen free tips.


Product detail pictures:

PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures


Related Product Guide:

Persisting in "High top quality, Prompt Delivery, Aggressive Price", now we have established long-term cooperation with customers from the two overseas and domestically and get new and aged clients' large comments for PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo , The product will supply to all over the world, such as: El Salvador, Mexico, America, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Let us work together to write a brilliant new chapter!
  • Sales manager is very enthusiastic and professional, gave us a great concessions and product quality is very good,thank you very much!
    5 Stars By Naomi from Gabon - 2018.03.03 13:09
    This company has the idea of "better quality, lower processing costs, prices are more reasonable", so they have competitive product quality and price, that's the main reason we chose to cooperate.
    5 Stars By Meredith from Croatia - 2018.02.04 14:13

    Leave Your Messages

    Related products

    • Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory Cheap Hot limulus amebocyte lysate kit ...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Manufacturer of Endotoxin LAL Testing - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Manufacturer of Endotoxin LAL Testing - LAL Re...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • 2022 China New Design LAL chromogenic test - Endpoint Chromogenic Kit EC64405 – Bioendo

      2022 China New Design LAL chromogenic test - E...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Good quality Depyrogenated tips box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Good quality Depyrogenated tips box - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale Kinetic Turbidimetric TAL Test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Kinetic Turbidimetric TAL Test - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • OEM/ODM Supplier Bacterial Endotoxin Test Kit Suppliers - Endotoxin-free Glass Test Tubes – Bioendo

      OEM/ODM Supplier Bacterial Endotoxin Test Kit S...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...