Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo


Product Detail

Related Video

Feedback (2)

With the "Client-Oriented" business philosophy, a rigorous quality control system, advanced manufacturing equipment and a strong R&D team, we always provide high quality products, excellent services and competitive prices for Endotoxin And Bioburden Testing, Endotoxin LAL Assay, Endotoxin Determination, Our experienced specialized group will be wholeheartedly at your support. We sincerely welcome you to check out our site and enterprise and send out us your inquiry.
Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo Detail:

Kinetic Turbidimetric Amebocyte Lysate Vial

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. 

2. Product Parameter:

Assay range:0.005-50EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Water for injection endotoxin assay, raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

ml/vial

Tests/Vial

Vials/Pack

Sensitivity EU/ml

KT17

1.7

16

10

0.01-10EU/ml

KT17S

 1.7

 16

 10

0.005-5EU/ml, 0.01-10EU/ml

KT52

5.2

50

10 

0.01-10EU/ml

KT52S

 5.2

 50

10 

0.005-5EU/ml, 0.01-10EU/ml

 

Product Condition:

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayedagainst USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come withproduct instruction, Certificate of Analysis.


Product detail pictures:

Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures


Related Product Guide:

No matter new buyer or old purchaser, We believe in long expression and trusted relationship for Good quality Turbidimetric LAL test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo , The product will supply to all over the world, such as: Washington, Hungary, Sri Lanka, What You Need Is What We Pursue.We are sure our products will bring you first class quality.And now sincerely hope to promote partner friendship with you from all over the world. Let's joint hands to cooperate with mutual benefits!
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Arabela from UK - 2017.05.02 18:28
    This company can be well to meet our needs on product quantity and delivery time, so we always choose them when we have procurement requirements.
    5 Stars By Kim from Boston - 2018.06.30 17:29

    Leave Your Messages

    Related products

    • 8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      8 Year Exporter Endotoxin LAL Test - Beta-gluc...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Professional China LAL assay - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Professional China LAL assay - Endotoxin Assay...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Best-Selling Endotoxin Lipopolysaccharide - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Best-Selling Endotoxin Lipopolysaccharide - Py...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • OEM Customized Endotixins - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM Customized Endotixins - Rapid Gel Clot 10 ...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • High Quality Kinetic Chromogenic Endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      High Quality Kinetic Chromogenic Endotoxin test...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Massive Selection for Endotoxin Cleaning - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Massive Selection for Endotoxin Cleaning - Bet...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...