Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo


Product Detail

Related Video

Feedback (2)

We thinks what clients think, the urgency of urgency to act from the interests of a purchaser position of principle, allowing for greater top quality, decrease processing costs, price ranges are much more reasonable, won the new and aged prospects the support and affirmation for Endotoxin Detection Test Is Based On, Kinetic Turbidimetric vs Kinetic Chromogenic, Data Logger For Oven Validation, Quality is factory's life , Focus on customers' demand is the source of company survival and development, We adhere to honesty and good faith working attitude, looking forward to your coming !
Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo Detail:

Endotoxin-specific Lyophilized Amebocyte Lysate

1. Product Information
Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples with potential which are contaminated by ß-Glucan. Bioendo has two Endotoxin-specific Lyophilized Amebocyte Lysate. One is that operator needs to add 0.1ml Water for BET and 0.1ml sample solution to the ampoule of Endotoxin-specific Lyophilized Amebocyte Lysate respectively; the other is that 0.2ml sample solution could be added directly into the ampoule.

2. Product Parameter
Sensitivity range: 0.03, 0.06, 0.125, 0.25, 0.5EU/ml

3. Product Application

Endotoxin-specific Lyophilized Amebocyte Lysate is the optimal choice for endotoxin detection of samples contaminated by beta-glucan such as cellulose, fungi solution.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

ES010030

0.03

ES010060

0.06

ES010125

0.125

ES010250

0.25

ES010500

0.5

Product Condition: 

The sensitivity of Lyophilized Amebocyte Lysate and Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. Lyophilized Amebocyte Lysate kit comes with product instruction, Certificate of Analysis, MSDS. 

Lysate reagent + Matched Control standard endotoxin ( save cost than RSE, CSE vial is calibrated by RSE. )

BET water or called LAL reagent water

Endotoxin free tubes and tips

Above all materials are necessary in the operation of endotoxin test assay.


Product detail pictures:

Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures


Related Product Guide:

Our solutions are widely recognized and trusted by consumers and will meet up with constantly developing financial and social requires for Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo , The product will supply to all over the world, such as: Georgia, Turkey, Nicaragua, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
  • Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Myrna from Dominica - 2017.07.28 15:46
    High production efficiency and good product quality, fast delivery and completed after-sale protection, a right choice, a best choice.
    5 Stars By Eudora from Barbados - 2018.10.31 10:02

    Leave Your Messages

    Related products

    • High Quality for Bioendo - Rapid Gel Clot 10 Samples Kit – Bioendo

      High Quality for Bioendo - Rapid Gel Clot 10 S...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • High reputation 1000ul Pipette tip box - Compact Modular Dry Heat Incubator – Bioendo

      High reputation 1000ul Pipette tip box - Compa...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo

      Factory Cheap Hot LAL testing medical device &#...

      Fungi(1,3)-β-D-glucan Assay Kit Product information: (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorb...

    • Manufactur standard Endotossine LAL Test - Nymph X Water Purification System – Bioendo

      Manufactur standard Endotossine LAL Test - Nym...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Wholesale Price limulus lysate test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Wholesale Price limulus lysate test - Endotoxi...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • High definition Control Standard Endotoxin Preparation - Control Standard Endotoxin (CSE) – Bioendo

      High definition Control Standard Endotoxin Prep...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...