Our firm aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine consistently for Micro kinetic chromogenic endotoxin assay, Bacterial Endotoxin Limit For API, Kinetic chromogenic LAL Assay kit, We believe we will become a leader in developing and producing high quality products in both Chinese and international markets. We hope to cooperate with more friends for mutual benefits.
8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

Our pursuit and firm aim should be to "Always fulfill our buyer requirements". We carry on to produce and structure top-quality excellent solutions for equally our aged and new consumers and accomplish a win-win prospect for our consumers as well as us for 8 Year Exporter Endotoxin LAL Test - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Netherlands, France, Czech Republic, With many years good service and development, we've a professional international trade sales team. Our products have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Edwina from Palestine - 2018.12.22 12:52
    The product classification is very detailed that can be very accurate to meet our demand, a professional wholesaler.
    5 Stars By Elaine from Turkey - 2018.08.12 12:27

    Leave Your Messages

    Related products

    • Chinese Professional limulus amebocyte lysate - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Chinese Professional limulus amebocyte lysate -...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Reasonable price Depyrogenated tips - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      Reasonable price Depyrogenated tips - Kinetic ...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Factory wholesale Endotoxin Gel Clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      Factory wholesale Endotoxin Gel Clot - Gel Clo...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • China OEM Bacterial Endotoxin Test Principle - Endotoxin-free Glass Test Tubes – Bioendo

      China OEM Bacterial Endotoxin Test Principle -...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Factory wholesale Amebocyte Lysate - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory wholesale Amebocyte Lysate - Endotoxin...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • 2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      2022 China New Design Gel Clot Method - Gel Cl...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...