Well-run equipment, expert income workforce, and far better after-sales expert services; We are also a unified large family, anyone stick to the corporate value "unification, dedication, tolerance" for Kinetic chromogenic TAL test kit, Pipette tip, Endotoxin Indicator For Depyrogenation, We have confident that we can provide the high quality products at resonable price, good after-sales service to the customers. And we will create a bright future.
2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo Detail:

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling)

1. Product Information

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis. 

2. Product Parameter

Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)

                             0.1-1.0EU/ml (assay time about 16 minutes)

3. Product Features and Application

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

EC80545

Bioendo™ EC Endotoxin Test Kit

(End-point Chromogenic Assay,

Diazo Coupling),

80 Tests/Kit

5 Lyophilized Amebocyte Lysate, 1.7ml/vial;

4 Water for BET, 50ml/vial;

5 CSE;

5 Chromogenic Substrate, 1.7ml/vial;

5 Diazo Reagent 1, 10ml/vial;

5 Diazo Reagent 2, 10ml /vial;

5 Diazo Reagent 3, 10ml/vial;

0.1 – 1 EU/ml

EC80545S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/ml

Product Conditions

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC80545 and EC80545S, can read by regular spectrophotometer. 

Bioendo End point chromogenic endotoxin test kit series:
Endotoxin Free Tube
Pyrogen Free Tips
Pyrogen Free Microplates
normal Microplate reader
Water Bath or Dry Heat Incubator 

Product detail pictures:

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures


Related Product Guide:

We often stay with the principle "Quality Very first, Prestige Supreme". We have been fully committed to supplying our consumers with competitively priced high-quality goods, prompt delivery and skilled provider for 2022 High quality Chromogenic LAL assay - Endpoint Chromogenic Kit EC80545 – Bioendo , The product will supply to all over the world, such as: Spain, Egypt, Benin, We are looking forward to cooperating closely with you to our mutual benefits and top development. We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
  • Perfect services, quality products and competitive prices, we have work many times, every time is delighted, wish continue to maintain!
    5 Stars By Mario from Hanover - 2018.09.23 18:44
    It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
    5 Stars By Alice from Mongolia - 2017.01.28 18:53

    Leave Your Messages

    Related products

    • High Quality LAL Reagent - Rapid Gel Clot 10 Samples Kit – Bioendo

      High Quality LAL Reagent - Rapid Gel Clot 10 S...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • professional factory for Endotoxin Detection Test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      professional factory for Endotoxin Detection Te...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Hot-selling Pipette tip supplier - Rapid Gel Clot single test kit – Bioendo

      Hot-selling Pipette tip supplier - Rapid Gel C...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • China wholesale Chromogenic endotoxin detection - Endpoint Chromogenic Kit EC64405 – Bioendo

      China wholesale Chromogenic endotoxin detection...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Wholesale Dealers of Bacterial Endotoxin Test Sop - Endotoxin-free Glass Test Tubes – Bioendo

      Wholesale Dealers of Bacterial Endotoxin Test S...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • High Quality endotoxin assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      High Quality endotoxin assay - Pyrogen-free Mi...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...