Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo


Product Detail

Related Video

Feedback (2)

We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for limulus lysate assay, Pyrogen Free Tube, Endotoxin Detection Assay, To achieve reciprocal advantages, our company is widely boosting our tactics of globalization in terms of communication with overseas customers, fast delivery, the best quality and long-term cooperation.
Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo Detail:

Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir

1. Product information

These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog number MPC96 is the pyrogen-free 12 strip X 8 well 96-well plate, strips are individual wrapped.

2. Product parameter

Catalog No.

Description

MP96

Pyrogen-free 96-well Microplate with Lid

MPC96

Pyrogen-free 8 well 96-well Plate Strips, Individual Wrapped

RR5

Pyrogen-free Reagent Resevoir, 5pcs/pack

Endotoxin level: ≤0.0005 EU/well

3. Product feature and application

Endotoxin free microplate and pyrogen-free resevoir mainly used in the kits of end-point chromogenic endotoxin assay, kinetic turbidimetric endotoxin assay and kinetic chromogenic endotoxin assay. Bioendo have launched the micro kinetic chromogenic endotoxin test kit 

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; endotoxin free tips; endotoxin free microplates; endotoxin free sample bottles;

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the experiment.


Product detail pictures:

Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures


Related Product Guide:

Our growth depends on the superior equipment ,exceptional talents and continuously strengthened technology forces for Reliable Supplier Endotoxin Detection Assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo , The product will supply to all over the world, such as: Denmark, Mauritius, Macedonia, We have gained a lot of recognition among customers spread all across the world. They trust us and always give repetitive orders. Furthermore, mentioned below are some of the major factors that have played significant role in our tremendous growth in this domain.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Prima from Ecuador - 2017.02.14 13:19
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Andrew Forrest from Lebanon - 2018.04.25 16:46

    Leave Your Messages

    Related products

    • 2022 China New Design Kinetic Turbidimetric Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      2022 China New Design Kinetic Turbidimetric Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Factory Cheap Hot Chromogenic LAL test - Micro...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Chinese wholesale LAL test kit - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Chinese wholesale LAL test kit - Endotoxin Ass...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • China wholesale TAL Reagent - Rapid Gel Clot 10 Samples Kit – Bioendo

      China wholesale TAL Reagent - Rapid Gel Clot 1...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • High reputation 1000ul Pipette tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      High reputation 1000ul Pipette tip box - Rapid...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo

      High definition Chromogenic Endotoxin Testing &...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...