Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo


Product Detail

Related Video

Feedback (2)

Assume full accountability to fulfill all demands of our purchasers; attain continual advancements by marketing the advancement of our clientele; grow to be the final permanent cooperative partner of purchasers and maximize the interests of purchasers for LAL gel clot test, LAL reagent sensitivity, Pipette tip supplier, We welcome all of the purchasers and pals to contact us for mutual added benefits. Hope to do additional business enterprise along with you.
Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

Our primary target will be to provide our clients a serious and responsible small business relationship, supplying personalized attention to all of them for Reliable Supplier Endotoxin Detection Assay - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Philippines, Nairobi, Paraguay, Ensuring high product quality by choosing the best suppliers, now we have also implemented complete quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Geraldine from Mauritius - 2017.09.26 12:12
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Matthew Tobias from Puerto Rico - 2017.02.28 14:19

    Leave Your Messages

    Related products

    • Manufactur standard Endotossine LAL Test - Mini Dry Heat Incubator – Bioendo

      Manufactur standard Endotossine LAL Test - Min...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Massive Selection for Endotoxin Cleaning - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Massive Selection for Endotoxin Cleaning - Dep...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • OEM/ODM Factory Application Of LAL Test - Eight-channel Mechanical Pipette – Bioendo

      OEM/ODM Factory Application Of LAL Test - Eigh...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Cheap PriceList for Endotoxin free reservoir - Endotoxin-free Glass Test Tubes – Bioendo

      Cheap PriceList for Endotoxin free reservoir -...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...