Our development depends on the advanced equipment, excellent talents and continuously strengthened technology forces for Endotoxin Gel Clot Method, LAL endotoxin kit, Biochemical Nature Of Bacterial Endotoxin Is, Our hugely specialized process eliminates the component failure and offers our consumers unvarying high quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
2022 wholesale price TAL gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free tube for dilution of CSE is necessary. Operation of endotoxin detection by choice of Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial conforms to the USP, the EP.

2. Product Parameter

Gel clot assay single test glass vial

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instruments,

Suitable for end-product endotoxin testing before product released,

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog number Sensitivity (EU/ml) (IU/ml) Tests/Vial Vials/Pack
G020015 0.015 1 50
G020030 0.03 1 50
G020060 0.06 1 50
G020125 0.125 1 50
G020250 0.25 1 50
G020500 0.5 1 50

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G02:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G02 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:


Related Product Guide:

Along with the "Client-Oriented" small business philosophy, a rigorous high-quality handle system, highly developed producing machines and a powerful R&D group, we always supply high-quality products and solutions, fantastic services and aggressive costs for 2022 wholesale price TAL gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo , The product will supply to all over the world, such as: Iran, Los Angeles, Ethiopia, Our focus on product quality, innovation, technology and customer service has made us one of undisputed leaders worldwide in the field. Bearing the concept of "Quality First, Customer Paramount, Sincerity and Innovation" in our mind, We have achieved great progress in the past years. Clients are welcomed to buy our standard products, or send us requests. You will be impressed by our quality and price. Please contact us now!
The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
5 Stars By Kristin from United Arab emirates - 2017.11.12 12:31
The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
5 Stars By Christopher Mabey from US - 2018.12.22 12:52

Leave Your Messages

Related products

  • Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo

    Bottom price 250ul Pipette tip box - Rapid Gel...

    Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

  • 2022 Latest Design Bioburden And Endotoxin Testing - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

    2022 Latest Design Bioburden And Endotoxin Test...

    Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

  • Wholesale Price China Bacterial Endotoxin Test By Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

    Wholesale Price China Bacterial Endotoxin Test ...

    Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

  • OEM Factory for Endotoxin Detection Methods - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

    OEM Factory for Endotoxin Detection Methods - ...

    Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

  • Wholesale Price Kinetic Turbidimetric LAL kit - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

    Wholesale Price Kinetic Turbidimetric LAL kit -...

    Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

  • OEM/ODM Supplier Bacterial Endotoxin Test Kit Suppliers - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

    OEM/ODM Supplier Bacterial Endotoxin Test Kit S...

    Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...