Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo


Product Detail

Related Video

Feedback (2)

Our progress depends around the innovative machines, great talents and consistently strengthened technology forces for BET Test In Pharma, Kinetic Turbidimetric Endotoxin test Kit, Endotoxin Kits, As a key enterprise of this industry, our company makes efforts to become a leading supplier, based on the faith of professional quality & worldwide service.
Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo Detail:

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

1. Product Information

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin concentration of test sample could be calculated based on a standard curve.

2. Product parameter

Sensitivity Range: 0.01-0.1 EU/ml, matching assay time is about 46 minutes

                              0.1-1 EU/ml, matching assay time is about 16 minutes. 

3. Product Features and Application

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into the mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. Yellow color develops if test sample contains endotoxin. Then use regular spectrophotometer or plate reader to read the absorbance at 405nm. End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is suitable for all kinds of biomedical samples such as protein, vaccine, plasmid, DNA, RNA endotoxin assay. 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

(EU/ml)

EC64405

 

Bioendo™ EC Endotoxin Test Kit (End-point Chromogenic Assay),

64 Tests/Kit

 

2 Lyophilized Amebocyte Lysate, 1.7ml/vial;

2 Water for BET, 50ml/vial;  

2 CSE;

4 Chromogenic Substrate, 1.7ml/vial;

0.1 – 1 EU/ml

EC64405S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/m

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC64405 and EC64405S kit analysis the quantitative endotoxin results through regular microplate reader. 

End point chromogenic endotoxin test kit series:

Endotoxin Free Tube

Pyrogen Free Tips

Pyrogen Free Microplates

Regular Microplate reader

Matched Control standard endotoxin (CSE10V)

BET water use for reconstitution. 

 



Product detail pictures:

Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures


Related Product Guide:

Our progress depends about the advanced products ,fantastic talents and continuously strengthened technology forces for Professional China Chromogenic endotoxin test - Endpoint Chromogenic Kit EC64405 – Bioendo , The product will supply to all over the world, such as: Mauritius, Swiss, Angola, Adhering to the principle of "Enterprising and Truth-Seeking, Preciseness and Unity", with technology as the core, our company continues to innovate, dedicated to providing you with the highest cost-effective solutions and meticulous after-sales service. We firmly believe that: we're outstanding as we have been specialized.
  • The quality of the products is very good, especially in the details, can be seen that the company work actively to satisfy customer's interest, a nice supplier.
    5 Stars By Julia from Oslo - 2017.02.28 14:19
    The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Daphne from Moldova - 2017.11.11 11:41

    Leave Your Messages

    Related products

    • 100% Original Endotoxin free glass tube - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      100% Original Endotoxin free glass tube - Depy...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Chinese wholesale Chromogenic endotoxin assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Chinese wholesale Chromogenic endotoxin assay -...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Well-designed Bacterial Endotoxin Calculation - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Hot New Products LAL reagent sensitivity - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot New Products LAL reagent sensitivity - Rap...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Manufacturer for Chromogenic endotoxin detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Manufacturer for Chromogenic endotoxin detectio...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Hot-selling LAL Turbidimetric test - Kinetic T...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...