To create more value for customers is our business philosophy; customer growing is our working chase for Rapid Gel Clot Assay, BET Testing, Endotoxin Bacteria, Competitive price with high quality and satisfying service make us earned more customers.we wish to work with you and seek common development.
Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo Detail:

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling)

1. Product Information

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis. 

2. Product Parameter

Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)

                             0.1-1.0EU/ml (assay time about 16 minutes)

3. Product Features and Application

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

EC80545

Bioendo™ EC Endotoxin Test Kit

(End-point Chromogenic Assay,

Diazo Coupling),

80 Tests/Kit

5 Lyophilized Amebocyte Lysate, 1.7ml/vial;

4 Water for BET, 50ml/vial;

5 CSE;

5 Chromogenic Substrate, 1.7ml/vial;

5 Diazo Reagent 1, 10ml/vial;

5 Diazo Reagent 2, 10ml /vial;

5 Diazo Reagent 3, 10ml/vial;

0.1 – 1 EU/ml

EC80545S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/ml

Product Conditions

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC80545 and EC80545S, can read by regular spectrophotometer. 

Bioendo End point chromogenic endotoxin test kit series:
Endotoxin Free Tube
Pyrogen Free Tips
Pyrogen Free Microplates
normal Microplate reader
Water Bath or Dry Heat Incubator 

Product detail pictures:

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures


Related Product Guide:

"Sincerity, Innovation, Rigorousness, and Efficiency" may be the persistent conception of our organization to the long-term to build together with shoppers for mutual reciprocity and mutual advantage for Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC80545 – Bioendo , The product will supply to all over the world, such as: Muscat, Mongolia, Saudi Arabia, If you have any requests, pls email Us with your detailed demands, we will give you the most wholesale Competitive Price with the Super Quality and the Unbeatable First-class Service ! We can give you the most competitive prices and high quality, because we are much more PROFESSIONAL! So please do not hesitate to contact us.
  • Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Quyen Staten from Sri Lanka - 2018.07.27 12:26
    The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Fernando from Rome - 2017.11.29 11:09

    Leave Your Messages

    Related products

    • Good quality Turbidimetric LAL test - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Good quality Turbidimetric LAL test - Bioendo ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Manufacturing Companies for Advantages Of LAL Test - Mini Dry Heat Incubator – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Reliable Supplier Endotoxin Detection Assay - Control Standard Endotoxin (CSE) – Bioendo

      Reliable Supplier Endotoxin Detection Assay - ...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • 2022 Latest Design Bioburden And Endotoxin Testing - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo

      High definition Chromogenic Endotoxin Testing &...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Manufacturer for Chromogenic endotoxin detection - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Manufacturer for Chromogenic endotoxin detectio...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...