OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo


Product Detail

Related Video

Feedback (2)

Our advantages are lessen charges,dynamic income team,specialized QC,sturdy factories,premium quality services for Chromogenic assays, Kinetic chromogenic LAL Assay kit, TAL test, Striving hard to attain continual success based on quality, reliability, integrity, and complete understanding of market dynamics.
OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

We have been ready to share our knowledge of internet marketing worldwide and recommend you suitable merchandise at most aggressive rates. So Profi Tools present you very best price of money and we are ready to develop alongside one another with OEM/ODM China Rapid Endotoxin Detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: Johannesburg, Chile, USA, To have much more enterprise. ompanions, we've got updated the item list and seek for optimistic co-operation. Our web-site shows the latest and complete information and facts about our merchandise list and company. For further acknowledge, our consultant service group in Bulgaria will reply to all of the inquiries and complications immediately. They're about to make their finest effort to meet buyers need. Also we support the delivery of absolutely free samples. Business visits to our business in Bulgaria and factory are generally welcome for a win-win negotiation. Hope to expertise a happy company co-operation perform with you.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Candy from Greece - 2017.09.29 11:19
    Factory equipment is advanced in the industry and the product is fine workmanship, moreover the price is very cheap, value for money!
    5 Stars By jari dedenroth from Naples - 2017.12.31 14:53

    Leave Your Messages

    Related products

    • Factory Supply Endotoxin Free Water - Control Standard Endotoxin (CSE) – Bioendo

      Factory Supply Endotoxin Free Water - Control ...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Good Quality Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Good Quality Gel Clot Assay - Gel Clot Lyophil...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • OEM Factory for BET Test Principle - Rapid Gel Clot single test kit – Bioendo

      OEM Factory for BET Test Principle - Rapid Gel...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM manufacturer BET Testing Method - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM manufacturer BET Testing Method - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Rapid Delivery for Endotoxin Producing Bacteria - Control Standard Endotoxin (CSE) – Bioendo

      Rapid Delivery for Endotoxin Producing Bacteria...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • OEM/ODM China Kinetic chromogenic TAL test kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      OEM/ODM China Kinetic chromogenic TAL test kit ...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...