Fast and great quotations, informed advisers to help you choose the correct product that suits all your preferences, a short creation time, responsible top quality control and different services for paying and shipping affairs for BET Test Method, endotoxin detection, Kinetic chromogenic TAL test, "Quality first, Price lowest, Service best" is the spirit of our company. We sincerely welcome you to visit our company and negotiate mutual business!
Factory supplied Bacterial Endotoxins – Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

Factory supplied Bacterial Endotoxins – Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Factory supplied Bacterial Endotoxins – Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Factory supplied Bacterial Endotoxins – Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

To be able to give you benefit and enlarge our business, we also have inspectors in QC Team and assure you our greatest service and products for Factory supplied Bacterial Endotoxins – Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: Hanover, Denver, Bahamas, our qualify products have good reputation from the world as its most competive price and our most advantage of after-sale service to the clients.we hope we can provide a safe, environmental products and super service to our clients from all of the world and establish strategic partnership with them by our professional standards and unremitting efforts.
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Odelia from Danish - 2018.09.19 18:37
    Staff is skilled, well-equipped, process is specification, products meet the requirements and delivery is guaranteed, a best partner!
    5 Stars By Christopher Mabey from Czech - 2017.09.09 10:18

    Leave Your Messages

    Related products

    • High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo

      High definition Chromogenic Endotoxin Testing &...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 2022 Latest Design Bioburden And Endotoxin Testing - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Discount wholesale BET Endotoxin - Control Standard Endotoxin (CSE) – Bioendo

      Discount wholesale BET Endotoxin - Control Sta...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • 2022 China New Design Kinetic Turbidimetric Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      2022 China New Design Kinetic Turbidimetric Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • PriceList for LAL Method - Rapid Gel Clot single test kit – Bioendo

      PriceList for LAL Method - Rapid Gel Clot sing...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Hot sale Kinetic Turbidimetric TAL Assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Hot sale Kinetic Turbidimetric TAL Assay - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...