All we do is usually affiliated with our tenet " Buyer to start with, Belief to start with, devoting about the food packaging and environmental defense for Endpoint Chromogenic Endotoxin test kit, BET Endotoxin, Dry heat sterilizer validation by ECV, Leading the trend of this field is our persistent objective. Supplying first class solutions is our intention. To create a beautiful upcoming, we wish to cooperate with all close friends in the home and overseas. Should you have got any interest in our products and solutions, remember to never wait to call us.
OEM Supply BET Test Method - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo Detail:

Kinetic Incubating Microplate Reader

1. Product information

Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be scaled up toautomatic performance.

2. Instrument parameters

- wavelength range of 340-900 nm, suitable for ultraviolet and visible light detection.

- 6 filter wheel, standard configuration with 5 filters (340,405, 490, 540 and 630 nm).

- temperature control range: room temperature+5℃ to 50℃

- standard curve linear correlation coefficient: |r|≥0.99

- assay repeatability: CV≤5%

- 96 tests per plate

3.  Application range:

- Bacterial endotoxin (pyrogen) assay of drugs, vaccines, Water for Injection medical devices, infusion, transfusion related devices dialysate,dialysis water endotoxin testing cell suspension, cell culture media, cell culture related products recombinant protein, nucleic acid and other molecular biological products

-Endotoxin level monitoring during production: pharmaceutical raw materials, intermediate products, end product endotoxin daily monitoring.

-Clinical diagnostic of sepsis and invasive fungi disease:plasma, serum, urine, cerebrospinal fluid endotoxin and (1,3)-beta-D-glucandetection.

Catalog No.

Description

KPR808IULAL

Kinetic incubating microplate reader Elx808  for Endotoxin and ß-glucan detection

20180903103214_47978

Please contact sales@houshiji.com to order the LAL reagents endotoxin detection kit.

There is no minimal order volume required.

The price depends on the order quantity. We provide distributor discount for our partners.

Bioendo provide professional transport services for sophisticated instruments to make sure safety international transportation.

 

Kinetic microplate incubating reader +

Quantitative Lysate reagent +

Pyrogen free microplate +

Pyrogen free tips.


Product detail pictures:

OEM Supply BET Test Method - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

OEM Supply BET Test Method - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

OEM Supply BET Test Method - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures


Related Product Guide:

Bear "Customer 1st, Good quality first" in mind, we work closely with our prospects and supply them with efficient and professional services for OEM Supply BET Test Method - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo , The product will supply to all over the world, such as: Ecuador, Norwegian, Algeria, All our staffs believe that: Quality builds today and service creates future. We know that good quality and the best service are the only way for us to achieve our customers and to achieve ourselves too. We welcome customers all over the word to contact us for future business relationships. Our products are the best. Once Selected, Perfect Forever!
  • It can be said that this is a best producer we encountered in China in this industry, we feel lucky to work with so excellent manufacturer.
    5 Stars By Danny from Jersey - 2017.01.28 18:53
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Meredith from Sacramento - 2017.05.02 11:33

    Leave Your Messages

    Related products

    • Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Low price for Chromogenic LAL Endotoxin Assay K...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • 2022 Latest Design Bioburden And Endotoxin Testing - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      2022 Latest Design Bioburden And Endotoxin Test...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Wholesale Price limulus lysate test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Wholesale Price limulus lysate test - Endotoxi...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Fast delivery Chromogenic Endotoxin Testing – Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Fast delivery Chromogenic Endotoxin Testing ...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Hot sale Kinetic Turbidimetric TAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Hot sale Kinetic Turbidimetric TAL Assay - Bio...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Special Design for Bacterial Endotoxin Test Methods - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Special Design for Bacterial Endotoxin Test Met...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...