OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

We regularly perform our spirit of ''Innovation bringing progress, Highly-quality making certain subsistence, Administration marketing benefit, Credit score attracting customers for endotoxin removal, Bacterial Endotoxin Test Usp Limit, Endotoxin Gel Clot Assay, We imagine we'll become a leader in building and producing high quality products in equally Chinese and international markets. We hope to cooperate with a lot more friends for mutual added benefits.
OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo detail pictures

OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

Our products and solutions are greatly recognized and trustworthy by customers and may fulfill constantly changing financial and social requires for OEM China BET Testing - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Ecuador, Iraq, Albania, It using the world's leading system for reliable operation, a low failure rate, it suitable for Argentina customers choice. Our company is situated within the national civilized cities, the traffic is very convenient, unique geographical and economic conditions. We pursue a people-oriented, meticulous manufacturing, brainstorm, build brilliant" business philosophy. Strict quality management, perfect service, reasonable price in Argentina is our stand on the premise of competition. If necessary, welcome to contact us by our website or phone consultation, we will be happy to serve you.
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Ida from Netherlands - 2017.08.18 18:38
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Priscilla from Amsterdam - 2017.10.25 15:53

    Leave Your Messages

    Related products

    • OEM Supply BET Test Method - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      OEM Supply BET Test Method - Endotoxin Assay a...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • PriceList for Kinetic chromogenic LAL Assay - Endpoint Chromogenic Kit EC80545 – Bioendo

      PriceList for Kinetic chromogenic LAL Assay - ...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Fast delivery 1000ul Pipette tip - Vortex Mixer – Bioendo

      Fast delivery 1000ul Pipette tip - Vortex Mixe...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Wholesale Price Chromogenic assays - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Wholesale Price Chromogenic assays - Bioendo K...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • OEM Customized Bacterial Endotoxins Test - Pyrogen-free Pipette tips and Consumables – Bioendo

      OEM Customized Bacterial Endotoxins Test - Pyr...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Wholesale Price China LAL chromogenic assay - Endpoint Chromogenic Kit EC64405 – Bioendo

      Wholesale Price China LAL chromogenic assay - ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...