New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo


Product Detail

Related Video

Feedback (2)

We emphasize progress and introduce new solutions into the market each year for Endosafe LAL Kit, LAL gel clot test, endotoxin removal, We welcome new and previous customers from all walks of lifetime to speak to us for future organization relationships and mutual achievement!
New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo Detail:

Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay)

1. Product Information

In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BET. Endotoxin detection with Kinetic Chromogenic method requires a kinetic incubating microplate reader such as ELx808IULALXH.

 

2. Product Parameter

Assay Range: 0.005 – 50EU/ml; 0.001 – 10EU/ml

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KC5028

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

1300 Tests/Kit

50 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

50 Reconstitution Buffer, 3.0ml/vial; 

10CSE; 

0.005-5EU/ml

KC5028S

0.001-10EU/ml

KC0828

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

 208 Tests/Kit

8 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 

2 Water for BET, 50ml/vial;

0.005-5EU/ml

KC0828S

0.001-10EU/ml

KC5017

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

800 Tests/Kit

50 Chromogenic Amebocyte Lysate,

1.7ml (16 Tests/Vial);

50 Reconstitution Buffer, 2.0ml/vial; 

10CSE; 

0.005-5 EU/ml

KC5017S

0.001-10 EU/m

KC0817

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

128 Tests/kit

8 Kinetic Chromogenic Amebocyte Lysate, 

1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 2.0ml/vial;

4 CSE;

2 Water for BET, 50ml/vial;

0.005-5 EU/ml

KC0817S

0.001-10 EU/ml

 

3. Product Feature and Application

BioendoTM KC Endotoxin Test Kit (Kinetic Chromogenic Assay) features strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. It is especially suitable for endotoxin detection of biological samples like vaccine, antibody, protein, nucleic acid, etc.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis. 

The kinetic chromogenic endotoxin test kit have to choose the microplate reader with 405nm filters.


Product detail pictures:

New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures


Related Product Guide:

We always believe that one's character decides products' quality, the details decides products' high-quality ,together with the REALISTIC,EFFICIENT AND INNOVATIVE crew spirit for New Arrival China Kinetic chromogenic TAL Assay kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo , The product will supply to all over the world, such as: Afghanistan, kazakhstan, Sheffield, We've been consistently broadening the market within Romania in addition to preparation punching in extra premium quality merchandise connected with printer on t shirt so that you can Romania. Most people firmly believe we've the whole capacity to provide you happy solutions.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Belinda from Qatar - 2018.11.28 16:25
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Edith from Pretoria - 2018.02.21 12:14

    Leave Your Messages

    Related products

    • High definition LAL Turbidimetric detection - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      High definition LAL Turbidimetric detection - ...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC64405 – Bioendo

      High definition Chromogenic Endotoxin Testing &...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • China Cheap price LAL gel clot method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      China Cheap price LAL gel clot method - Gel Cl...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

    • High Performance Endotoxin Detection Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      High Performance Endotoxin Detection Method - ...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • High Quality Kinetic Chromogenic Endotoxin test kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      High Quality Kinetic Chromogenic Endotoxin test...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 100% Original Endotoxin free glass tube - Endotoxin-free Glass Test Tubes – Bioendo

      100% Original Endotoxin free glass tube - Endo...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...