Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo


Product Detail

Related Video

Feedback (2)

We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our administration ideal for Endotoxin Indicator, Bacterial Endotoxin Test By Gel Clot Method, Kinetic Turbidimetric TAL Kit, Safety as a result of innovation is our promise to each other.
Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo Detail:

Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series

1. Product Information

Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen.

As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial.

2. Product Parameters

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification, waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 50 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G520030 0.03 5.2 50 10
G520060 0.06 5.2 50 10
G520125 0.125 5.2 50 10
G520250 0.25 5.2 50 10
G520500 0.5 5.2 50 10

Product condition

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis, MSDS.

 

What is the difference between single test and multiple test?

● Single test: reconstitute the single test lysate reagent by BET water in the glass vial or glass ampoule.

● Multi-test: reconstitute the lysate reagent with BET water, and then add marked amount of lysate reagent following COA to the reaction tube or well plate for use. There is no difference in the sample pre-processing procedure; according to the amount of testing used, the sample size used for a single test is larger than the sample size used for multiple tests.

 

Why the most selected gel clot assay kit G52:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G52 series of Gel clot assay multi test glass vial no need sophisticated microplate reader. Procedure of incubation by water bath or dry heat incubator.

3. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tips (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures


Related Product Guide:

We also offer you product sourcing and flight consolidation expert services. We've our personal manufacturing unit and sourcing business. We can offer you virtually every variety of merchandise associated to our item range for Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo , The product will supply to all over the world, such as: Colombia, Bhutan, Philadelphia, Actually need to any of those objects be of interest to you, make sure you allow us to know. We'll be delighted to present you a quotation on receipt of one's comprehensive specs. We've our individual specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
  • The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Ray from Monaco - 2018.11.22 12:28
    We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Colin Hazel from Karachi - 2018.09.12 17:18

    Leave Your Messages

    Related products

    • Wholesale Price Endotoxin challenge vial - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Wholesale Price Endotoxin challenge vial - Pyr...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Super Purchasing for Endotoxin Method - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Super Purchasing for Endotoxin Method - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Reasonable price Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Reasonable price Chromogenic LAL Endotoxin Assa...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Best-Selling Endotoxin Lipopolysaccharide - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Best-Selling Endotoxin Lipopolysaccharide - Py...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Hot-selling LAL Turbidimetric test - Kinetic T...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo

      Bottom price 250ul Pipette tip box - Rapid Gel...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...