Each individual member from our large performance revenue crew values customers' needs and company communication for LAL assay, Bacterial Endotoxin Limit For API, Micro kinetic chromogenic endotoxin test kit, We are now looking forward to even greater cooperation with overseas customers based on mutual benefits. If you are interested in any of our products, please feel free to contact us for more details.
Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

With this motto in mind, we've got become among essentially the most technologically innovative, cost-efficient, and price-competitive manufacturers for Manufacturer for LAL reagent manufacturer - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Frankfurt, Honduras, Bulgaria, Our factory is equipped with complete facility in 10000 square meters, which makes us be able to satisfy the producing and sales for most auto part solutions. Our advantage is full category, high quality and competitive price! Based on that, our products win a high admiration both at home and abroad.
  • Wide range, good quality, reasonable prices and good service, advanced equipment, excellent talents and continuously strengthened technology forces,a nice business partner.
    5 Stars By Ray from Porto - 2018.12.05 13:53
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Olga from Orlando - 2017.12.19 11:10

    Leave Your Messages

    Related products

    • Manufacturing Companies for Advantages Of LAL Test - Eight-channel Mechanical Pipette – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • 2022 wholesale price Kinetic Turbidimetric vs Kinetic Chromogenic - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      2022 wholesale price Kinetic Turbidimetric vs K...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo

      Factory Cheap Hot LAL testing medical device &#...

      Fungi(1,3)-β-D-glucan Assay Kit Product information: (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorb...

    • Low price for Endotoxin Free Tube - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Low price for Endotoxin Free Tube - Depyrogena...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • New Arrival China Kinetic Turbidimetric Method endotoxin - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      New Arrival China Kinetic Turbidimetric Method ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Hot sale Endotoxin Indicator Vials Manufacturer - Control Standard Endotoxin (CSE) – Bioendo

      Hot sale Endotoxin Indicator Vials Manufacturer...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...