Well-run gear, qualified revenue workforce, and superior after-sales companies; We've been also a unified huge loved ones, anyone persist with the organization benefit "unification, determination, tolerance" for Test Endotoxine, TAL test, Kinetic Turbidimetric Method endotoxin, We are able to do your tailored get to fulfill your own satisfactory! Our organization sets up several departments, including manufacturing department, sales department, high quality control department and sevice center, etc.
Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures

Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

We stick to our enterprise spirit of "Quality, Performance, Innovation and Integrity". We purpose to create a lot more price for our prospects with our rich resources, innovative machinery, experienced workers and great products and services for Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: Namibia, Bolivia, Saudi Arabia, We are looking forward to cooperating closely with you to our mutual benefits and top development. We guaranteed quality, if customers were not satisfied with the products' quality, you can return within 7days with their original states.
  • The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Yannick Vergoz from Azerbaijan - 2017.01.28 18:53
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Laurel from Netherlands - 2017.01.28 18:53

    Leave Your Messages

    Related products

    • Best-Selling Endotoxin Lipopolysaccharide - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Best-Selling Endotoxin Lipopolysaccharide - De...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • 2022 High quality LAL gel clot test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      2022 High quality LAL gel clot test - Gel Clot...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • Manufacturer for Kinetic chromogenic TAL Assay - Endpoint Chromogenic Kit EC64405 – Bioendo

      Manufacturer for Kinetic chromogenic TAL Assay ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Excellent quality Turbidimetric endotoxin assay...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Good quality Depyrogenated tips box - Eight-channel Mechanical Pipette – Bioendo

      Good quality Depyrogenated tips box - Eight-ch...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Factory wholesale Kinetic Turbidimetric LAL Assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Factory wholesale Kinetic Turbidimetric LAL Ass...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...