We have state-of-the-art equipment. Our products are exported for the USA, the UK and so on, enjoying a fantastic status among the clients for Bacterial Endotoxin Test Usp Limit, LAL bacterial endotoxin test, Endotoxin Detection Method, We feel that our warm and professional support will bring you pleasant surprises as perfectly as fortune.
Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo Detail:

Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay)

1. Product Information

In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BET. Endotoxin detection with Kinetic Chromogenic method requires a kinetic incubating microplate reader such as ELx808IULALXH.

 

2. Product Parameter

Assay Range: 0.005 – 50EU/ml; 0.001 – 10EU/ml

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KC5028

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

1300 Tests/Kit

50 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

50 Reconstitution Buffer, 3.0ml/vial; 

10CSE; 

0.005-5EU/ml

KC5028S

0.001-10EU/ml

KC0828

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

 208 Tests/Kit

8 Chromogenic Amebocyte Lysate,

2.8ml (26 Tests/Vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 

2 Water for BET, 50ml/vial;

0.005-5EU/ml

KC0828S

0.001-10EU/ml

KC5017

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

800 Tests/Kit

50 Chromogenic Amebocyte Lysate,

1.7ml (16 Tests/Vial);

50 Reconstitution Buffer, 2.0ml/vial; 

10CSE; 

0.005-5 EU/ml

KC5017S

0.001-10 EU/m

KC0817

Bioendo™ KC Endotoxin Test Kit (Kinetic Chromogenic Assay),

128 Tests/kit

8 Kinetic Chromogenic Amebocyte Lysate, 

1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 2.0ml/vial;

4 CSE;

2 Water for BET, 50ml/vial;

0.005-5 EU/ml

KC0817S

0.001-10 EU/ml

 

3. Product Feature and Application

BioendoTM KC Endotoxin Test Kit (Kinetic Chromogenic Assay) features strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. It is especially suitable for endotoxin detection of biological samples like vaccine, antibody, protein, nucleic acid, etc.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis. 

The kinetic chromogenic endotoxin test kit have to choose the microplate reader with 405nm filters.


Product detail pictures:

Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures

Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo detail pictures


Related Product Guide:

We rely upon strategic thinking, constant modernisation in all segments, technological advances and of course upon our employees that directly participate in our success for Low price for Chromogenic LAL Endotoxin Assay Kit - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo , The product will supply to all over the world, such as: Philadelphia, Paraguay, Georgia, If you are for any reason unsure which product to select, do not hesitate to contact us and we will be delighted to advise and assist you. This way we will be providing you with all the knowledge needed to make the best choice. Our company strictly follows "Survive by good quality, Develop by keeping good credit. " operation policy. Welcome all the clients old and new to visit our company and talk about the business. We are looking for more and more customers to create the glorious future.
  • High Quality, High Efficiency, Creative and Integrity, worth having long-term cooperation! Looking forward to the future cooperation!
    5 Stars By Norma from Gabon - 2018.09.08 17:09
    This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Florence from UK - 2018.06.18 19:26

    Leave Your Messages

    Related products

    • Wholesale Price limulus lysate test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Wholesale Price limulus lysate test - Endotoxi...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Reasonable price Control Standard Endotoxin - Depyrogenated Sample Bottles ( Depyrogenated Galssware ) – Bioendo

      Reasonable price Control Standard Endotoxin - ...

      Depyrogenated Sample Bottle  1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipette tips, pyrogen free microplates and sample bottles for your conveniences. Amoung the sample bottle have two types, one is depyrogenated glassware and the other is depyrogenated plasticware, both endotoxin free level.  High quality depyrogenated low endotoxin pyrogen free products in...

    • Factory wholesale Endotoxin Gel Clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      Factory wholesale Endotoxin Gel Clot - Gel Clo...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

    • Factory Supply Pipette tip box - Rapid Gel Clot single test kit – Bioendo

      Factory Supply Pipette tip box - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • 2022 Good Quality TAL assay kit - Mini Dry Heat Incubator – Bioendo

      2022 Good Quality TAL assay kit - Mini Dry Hea...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...