We retain improving upon and perfecting our items and repair. At the same time, we perform actively to do research and progress for Depyrogenated tips, BET Bacterial Endotoxin Test, Endotoxin Analysis Methods, The team of our company along with the use of cutting-edge technologies delivers impeccable top quality products supremely adored and appreciated by our shoppers worldwide.
OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo Detail:

Kinetic Incubating Microplate Reader

1. Product information

Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be scaled up toautomatic performance.

2. Instrument parameters

- wavelength range of 340-900 nm, suitable for ultraviolet and visible light detection.

- 6 filter wheel, standard configuration with 5 filters (340,405, 490, 540 and 630 nm).

- temperature control range: room temperature+5℃ to 50℃

- standard curve linear correlation coefficient: |r|≥0.99

- assay repeatability: CV≤5%

- 96 tests per plate

3.  Application range:

- Bacterial endotoxin (pyrogen) assay of drugs, vaccines, Water for Injection medical devices, infusion, transfusion related devices dialysate,dialysis water endotoxin testing cell suspension, cell culture media, cell culture related products recombinant protein, nucleic acid and other molecular biological products

-Endotoxin level monitoring during production: pharmaceutical raw materials, intermediate products, end product endotoxin daily monitoring.

-Clinical diagnostic of sepsis and invasive fungi disease:plasma, serum, urine, cerebrospinal fluid endotoxin and (1,3)-beta-D-glucandetection.

Catalog No.

Description

KPR808IULAL

Kinetic incubating microplate reader Elx808  for Endotoxin and ß-glucan detection

20180903103214_47978

Please contact sales@houshiji.com to order the LAL reagents endotoxin detection kit.

There is no minimal order volume required.

The price depends on the order quantity. We provide distributor discount for our partners.

Bioendo provide professional transport services for sophisticated instruments to make sure safety international transportation.

 

Kinetic microplate incubating reader +

Quantitative Lysate reagent +

Pyrogen free microplate +

Pyrogen free tips.


Product detail pictures:

OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures


Related Product Guide:

We offer fantastic energy in high quality and enhancement,merchandising,profits and promoting and procedure for OEM/ODM China Dry heat sterilizer validation by ECV - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo , The product will supply to all over the world, such as: Swaziland, Vancouver, Adelaide, Profession, Devoting are always fundamental to our mission. We've got always been in line with serving customers, creating value management objectives and adhering to the sincerity, dedication, persistent management idea.
  • Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By trameka milhouse from kazakhstan - 2018.02.21 12:14
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Nana from Canada - 2017.11.01 17:04

    Leave Your Messages

    Related products

    • Quality Inspection for Endotoxin Kits - Endotoxin-free Glass Test Tubes – Bioendo

      Quality Inspection for Endotoxin Kits - Endoto...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Hot New Products LAL reagent sensitivity - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot New Products LAL reagent sensitivity - Rap...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Fast delivery Endotoxin Free tip - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Fast delivery Endotoxin Free tip - Beta-glucan...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • High definition LAL Turbidimetric detection - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      High definition LAL Turbidimetric detection - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Low MOQ for Bacterial Endotoxins Test Usp - Control Standard Endotoxin (CSE) – Bioendo

      Low MOQ for Bacterial Endotoxins Test Usp - Co...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Quality Inspection for Endotoxin Kits - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Quality Inspection for Endotoxin Kits - Depyro...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...