Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo


Product Detail

Related Video

Feedback (2)

We normally believe that one's character decides products' quality, the details decides products' high-quality ,while using the REALISTIC,EFFICIENT AND INNOVATIVE staff spirit for limulus amebocyte lysate price, LAL gel clot, Kinetic chromogenic TAL test, We welcome new and previous customers from all walks of lifestyle to contact us for long run organization relationships and mutual achievements.
Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo Detail:

Kinetic Turbidimetric Amebocyte Lysate Vial

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. 

2. Product Parameter:

Assay range:0.005-50EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Water for injection endotoxin assay, raw material endotoxin testing or endotoxin level monitoring during manufacturing process for pharmaceutical companies or medical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

ml/vial

Tests/Vial

Vials/Pack

Sensitivity EU/ml

KT17

1.7

16

10

0.01-10EU/ml

KT17S

 1.7

 16

 10

0.005-5EU/ml, 0.01-10EU/ml

KT52

5.2

50

10 

0.01-10EU/ml

KT52S

 5.2

 50

10 

0.005-5EU/ml, 0.01-10EU/ml

 

Product Condition:

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayedagainst USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come withproduct instruction, Certificate of Analysis.


Product detail pictures:

Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures

Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo detail pictures


Related Product Guide:

Our advancement depends over the superior machines, exceptional talents and continually strengthened technology forces for Hot-selling LAL Turbidimetric test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo , The product will supply to all over the world, such as: Philippines, Zambia, Peru, The working experience in the field has helped us forged a strong relations with customers and partners both in domestic and international market. For years, our products have been exported to more than 15 countries in the world and have been widely used by customers.
  • The company can think what our think, the urgency of urgency to act in the interests of our position, can be said this is a responsible company, we had a happy cooperation!
    5 Stars By Priscilla from Greece - 2018.06.03 10:17
    The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Julie from Lahore - 2018.06.05 13:10

    Leave Your Messages

    Related products

    • PriceList for Pyrogen Free Tube - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      PriceList for Pyrogen Free Tube - Kinetic Incu...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • OEM Factory for BET Test Principle - Vortex Mixer – Bioendo

      OEM Factory for BET Test Principle - Vortex Mi...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Factory wholesale Kinetic Turbidimetric LAL Assay - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Factory wholesale Kinetic Turbidimetric LAL Ass...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory Cheap Hot limulus amebocyte lysate kit ...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • New Delivery for Biochemical Nature Of Bacterial Endotoxin Is - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      New Delivery for Biochemical Nature Of Bacteria...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • OEM Customized Bacterial Endotoxins Test - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      OEM Customized Bacterial Endotoxins Test - Pyr...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...