High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo


Product Detail

Related Video

Feedback (2)

We will constantly satisfy our respected customers with our good excellent, superior value and superior assistance due to we're additional experienced and far more hard-working and do it in cost-effective way for Endotoxin Indicator For Depyrogenation, Kinetic Turbidimetric TAL Kit, Amoebocyte Lysate, First business, we learn each other. Further business, the trust is getting there. Our company always at your service at any time.
High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo Detail:

Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series

1. Product Information

Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen.

As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial.

2. Product Parameters

Sensitivity range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml 

3. Product Application

End-product endotoxin (pyrogen) qualification, waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Gel clot method LAL assay, reconstituted lysate reagent get at least 50 tests per vial:
Catalog Number Sensitivity (EU/ml or IU/ml) ml/vial Tests/Vial Vials/Pack
G520030 0.03 5.2 50 10
G520060 0.06 5.2 50 10
G520125 0.125 5.2 50 10
G520250 0.25 5.2 50 10
G520500 0.5 5.2 50 10

Product condition

The Lyophilized Amebocyte Lysate reagent sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte reagent kits come with product instruction, Certificate of Analysis, MSDS.

 

What is the difference between single test and multiple test?

● Single test: reconstitute the single test lysate reagent by BET water in the glass vial or glass ampoule.

● Multi-test: reconstitute the lysate reagent with BET water, and then add marked amount of lysate reagent following COA to the reaction tube or well plate for use. There is no difference in the sample pre-processing procedure; according to the amount of testing used, the sample size used for a single test is larger than the sample size used for multiple tests.

 

Why the most selected gel clot assay kit G52:

1. Multi test reagent for endotoxin detection in the applications of certain samples’ endotoxin detection.

2. G52 series of Gel clot assay multi test glass vial no need sophisticated microplate reader. Procedure of incubation by water bath or dry heat incubator.

3. High end quality of endotoxin free tube (<0.005EU/ml) and High quality of pyrogen free tips (<0.005EU/ml) as the guaranteed consumables to ensure the correct result.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018 and T107540
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10V.

Product detail pictures:

High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures

High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo detail pictures


Related Product Guide:

Together with the "Client-Oriented" enterprise philosophy, a arduous good quality control technique, sophisticated producing equipment and a sturdy R&D staff, we generally offer superior quality merchandise, superb solutions and aggressive rates for High Quality LAL test gel clot - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo , The product will supply to all over the world, such as: Australia, Brunei, Slovak Republic, Our factory is equipped with complete facility in 10000 square meters, which makes us be able to satisfy the producing and sales for most auto part solutions. Our advantage is full category, high quality and competitive price! Based on that, our products win a high admiration both at home and abroad.
  • We have been engaged in this industry for many years, we appreciate the work attitude and production capacity of the company, this is a reputable and professional manufacturer.
    5 Stars By Martin Tesch from Vancouver - 2018.11.28 16:25
    Although we are a small company, we are also respected. Reliable quality, sincere service and good credit, we are honored to be able to work with you!
    5 Stars By Jamie from United Arab emirates - 2018.09.23 18:44

    Leave Your Messages

    Related products

    • OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      OEM/ODM China Kinetic Turbidimetric Method of e...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Factory wholesale TAL Reagent Water - Rapid Gel Clot 10 Samples Kit – Bioendo

      Factory wholesale TAL Reagent Water - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Fast delivery Chromogenic Endotoxin Testing – Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Fast delivery Chromogenic Endotoxin Testing ...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • China wholesale TAL Reagent - Compact Modular Dry Heat Incubator – Bioendo

      China wholesale TAL Reagent - Compact Modular ...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • 2022 China New Design LAL chromogenic test - Endpoint Chromogenic Kit EC80545 – Bioendo

      2022 China New Design LAL chromogenic test - E...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • 8 Year Exporter Define LAL Test - Compact Modular Dry Heat Incubator – Bioendo

      8 Year Exporter Define LAL Test - Compact Modu...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...