High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo


Product Detail

Related Video

Feedback (2)

We have quite a few great team customers very good at internet marketing, QC, and dealing with kinds of troublesome trouble while in the output approach for Pipettor tip box, Endotoxin Cleaning, Endotoxin free reservoir, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo Detail:

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling)

1. Product Information

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis. 

2. Product Parameter

Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)

                             0.1-1.0EU/ml (assay time about 16 minutes)

3. Product Features and Application

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

EC80545

Bioendo™ EC Endotoxin Test Kit

(End-point Chromogenic Assay,

Diazo Coupling),

80 Tests/Kit

5 Lyophilized Amebocyte Lysate, 1.7ml/vial;

4 Water for BET, 50ml/vial;

5 CSE;

5 Chromogenic Substrate, 1.7ml/vial;

5 Diazo Reagent 1, 10ml/vial;

5 Diazo Reagent 2, 10ml /vial;

5 Diazo Reagent 3, 10ml/vial;

0.1 – 1 EU/ml

EC80545S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/ml

Product Conditions

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC80545 and EC80545S, can read by regular spectrophotometer. 

Bioendo End point chromogenic endotoxin test kit series:
Endotoxin Free Tube
Pyrogen Free Tips
Pyrogen Free Microplates
normal Microplate reader
Water Bath or Dry Heat Incubator 

Product detail pictures:

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures


Related Product Guide:

Our personnel are always in the spirit of "continuous improvement and excellence", and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer's rely on for High definition Chromogenic Endotoxin Testing – Endpoint Chromogenic Kit EC80545 – Bioendo , The product will supply to all over the world, such as: Algeria, Vancouver, India, If any product meed your demand, please feel free to contact us. We're sure your any inquiry or requirement will get prompt attention, high-quality products, preferential prices and cheap freight. Sincerely welcome friends all over the world to call or come to visit, to discuss cooperation for a better future!
  • We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Juliet from Sheffield - 2018.06.03 10:17
    This company conforms to the market requirement and joins in the market competition by its high quality product, this is an enterprise that have Chinese spirit.
    5 Stars By Dee Lopez from Japan - 2017.03.28 12:22

    Leave Your Messages

    Related products

    • Factory Price For Endotoxin Free Tubes - Endotoxin-free Glass Test Tubes – Bioendo

      Factory Price For Endotoxin Free Tubes - Endot...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Factory Cheap Hot Kinetic Turbidimetric Endotoxin test Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Factory Cheap Hot Kinetic Turbidimetric Endotox...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • OEM Customized Endotixins - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      OEM Customized Endotixins - Endotoxin Assay an...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...

    • Well-designed Bacterial Endotoxin Calculation - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Manufacturer of Endotoxin LAL Testing - Endotoxin-free Glass Test Tubes – Bioendo

      Manufacturer of Endotoxin LAL Testing - Endoto...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • OEM/ODM China Kinetic Chromogenic Endotoxin Assay Kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      OEM/ODM China Kinetic Chromogenic Endotoxin Ass...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...