Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo


Product Detail

Related Video

Feedback (2)

Our commission should be to provide our customers and consumers with ideal top quality and aggressive portable digital products for Bacterial Endotoxins Test, Chromogenic endotoxin assay, 250ul Pipette tip box, The continual availability of significant grade merchandise in combination with our excellent pre- and after-sales support ensures strong competitiveness in an increasingly globalized market.
Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit)

1. Product Information

Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes.
Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures in the operation of rapid endotoxin assay, the whole operation not required sophisticated experimental equipment, incubation by a dry heat incubator. It is especial suitable for the endotoxins analysis in the water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

One sample test in a kit. 

Assay time: less than 30 minutes. 

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, One Sample Kit

1 SPL Tube;

1 PPC Tube;

1 Endotoxin-free Sample Bottle;

3 Pyrogen-free Pipettors;

0.03

≤60

RG025006

0.06

≤60

RG0250125

0.125

≤45

RG025025

0.25

≤30

RG025050

0.5

≤30

 

3. Kit Application

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit provide a kind of rapid endotoxin testing solution, the featured application in the field of dialysis. 

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab. In the operation procedure,  the dilution of control standard endotoxin is simple and convenient. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instrument is not required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation. 

Kit Configuration:

Bioendo single test Rapid Gel Clot Endotoxin Assay Kit contains: 

1 piece of SPL Tube, 1 piece of PPC Tube, 1 piece of Endotoxin-free Sample Bottle. (endotoxin free top level), 

1 Pack of Transfer Pipette 3 pieces. (endotoxin free top level)


Product detail pictures:

Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo detail pictures

Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo detail pictures


Related Product Guide:

As a way to ideal meet up with client's desires, all of our operations are strictly performed in line with our motto "High Top quality, Competitive Cost, Fast Service" for Factory wholesale TAL Reagent Water - Rapid Gel Clot single test kit – Bioendo , The product will supply to all over the world, such as: San Francisco, Australia, Algeria, We warmly welcome domestic and overseas customers to visit our company and have business talk. Our company always insists on the principle of "good quality, reasonable price, the first-class service". We are willing to build long-term, friendly and mutually beneficial cooperation with you.
  • The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Brook from Sri Lanka - 2018.09.23 18:44
    This company has a lot of ready-made options to choose and also could custom new program according to our demand, which is very nice to meet our needs.
    5 Stars By Marjorie from Orlando - 2018.12.28 15:18

    Leave Your Messages

    Related products

    • China wholesale LAL gel clot - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo

      China wholesale LAL gel clot - Bioendo GC Endo...

      Bioendo GC Endotoxin Test Kit Bioendo GC Endotoxin Test Kit (Gel Clot Assay)  1. Product Information Bioendo GC Endotoxin Test Kit (Gel Clot Assay) contains 128 Tests/Kit, 400Tests/Kit, 1600Tests/Kit, and 4500 Tests/Kit. And sensitivity of Amebocyte Lysate included by the Kit is 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Kit contains Amebocyte Lysate, CSE and Water for BET. Four kinds of configuration of gel-clot endotoxin assay kit to satisfied the demand. This means yo...

    • Wholesale Dealers of Bacterial Endotoxin Test Sop - Pyrogen-free Pipette tips and Consumables – Bioendo

      Wholesale Dealers of Bacterial Endotoxin Test S...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • High reputation Endotoxin free tip box - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      High reputation Endotoxin free tip box - Beta-...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • OEM manufacturer Endotoxin Elisa Kit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      OEM manufacturer Endotoxin Elisa Kit - Beta-gl...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • China Factory for Endotoxin Analysis Methods - Control Standard Endotoxin (CSE) – Bioendo

      China Factory for Endotoxin Analysis Methods -...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Chinese wholesale Rapid Gel Clot Assay - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G17 – Bioendo

      Chinese wholesale Rapid Gel Clot Assay - Gel C...

      Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial, G17 series 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which choose gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 1.7ml per vial. 2. Product Parameter Sensitivity range: 0....