We stay with the basic principle of "quality initially, services first, steady improvement and innovation to fulfill the customers" for your management and "zero defect, zero complaints" as the quality objective. To perfect our company, we give the goods while using the good high-quality at the reasonable selling price for Endotoxin Producing Bacteria, LAL test kit, Endotoxin Bacteria, We feel that our warm and professional support will bring you pleasant surprises as perfectly as fortune.
Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo Detail:

Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.
The kit contains Lyophilized Amebocyte Lysate, Control Standard Endotoxin, and Water for BET. KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) require a kinetic microplate reader such as ELx808IULALXH or a kinetic tube reader. Kinetic software is also required for calculation of the endotoxin concentration.

2. Product Parameter

Assay Range: 0.005 – 5EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KT0817

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 128 tests/kit

8 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 2 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0817S

0.005-5EU/ml,

0.01-10EU/ml

KT0852

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 400 Tests/Kit

8 Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial);

8 Reconstitution Buffer, 6.0ml/vial;

4 CSE; 3 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0852S

0.005-5EU/ml,

0.01-10EU/ml

KT5017

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 800 Tests/Kit

50 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

50 Reconstitution Buffer, 3.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5017S

0.005-5EU/ml,

0.01-10EU/ml

KT5052

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 2500 Tests/Kit

50 Lyophilized Amebocyte Lysate,5.2ml (50 Tests/vial);

50 Reconstitution Buffer, 6.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5052S

0.005-5EU/ml,

0.01-10EU/ml

Product Condition:

The potency of Lyophilized Amebocyte Lysate and Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures


Related Product Guide:

Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for Factory Supply LAL Turbidimetric assay - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo , The product will supply to all over the world, such as: Croatia, Finland, Los Angeles, With well educated, innovative and energetic staff, we are responsible for all elements of research, design, manufacture, sale and distribution. By studying and developing new techniques, we are not only following but also leading fashion industry. We listen attentively to the feedback from our customers and provide instant replies. You will instantly feel our professional and attentive service.
  • The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Honorio from Georgia - 2017.08.18 11:04
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Honey from Miami - 2017.11.01 17:04

    Leave Your Messages

    Related products

    • OEM/ODM Factory Application Of LAL Test - Eight-channel Mechanical Pipette – Bioendo

      OEM/ODM Factory Application Of LAL Test - Eigh...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Top Quality Endotoxin - Endotoxin-free Glass Test Tubes – Bioendo

      Top Quality Endotoxin - Endotoxin-free Glass T...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • High definition Control Standard Endotoxin Preparation - Endotoxin-free Glass Test Tubes – Bioendo

      High definition Control Standard Endotoxin Prep...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo

      Manufactur standard Endotossine LAL Test - Rap...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Online Exporter Endotoxin Detection System - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Online Exporter Endotoxin Detection System - B...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Reasonable price Depyrogenated tips - Endotoxin Assay and (1,3)-ß-D-glucan assay software – Bioendo

      Reasonable price Depyrogenated tips - Endotoxi...

      Endotoxin and (1,3)-ß-D-glucan assay software 1. Product information Endotoxin and (1,3)-ß-D-glucan assay software is a powerful kinetic data analysis software,which gives the user data acquisition and processing of the maximum flexibility. Features: • Apply to Endotoxin assay,(1,3)-ß-D-glucan assay and ELISA data analysis • With standard version and clinical diagnostic version for the different user groups. • Data could be output transitions and connected to the LIS system. • Customizabl...