We take pleasure in an extremely fantastic standing among the our prospects for our great product top quality, competitive cost and the finest support for TAL assay kit, Bacterial Endotoxin Limit For Injection, Endotoxin LAL Method, We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo Detail:

 Endotoxin Challenge Vials (Endotoxin Indicator)

 

1. Product Information

The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3-log reduction in endotoxin content when tested using gel clot endotoxin assay kit, kinetic turbidimetric endotoxin assay kit or chromogenic Lyophilized Amebocyte Lysate assay kits. Endotoxin Challenge Vial contains 1000 to 10000EU Endotoxins level in a glass vial. ECV1250V and ECV2500V are sealed in vials that configurate the heat resistant stoppers and heat resistant labels, which could be placed in dry-heat oven or dry-heat tunnel without removal of stoppers and caps(lid).

Validation of dry heat sterilization cycle(s) is required by regulations of ANSI, AAMI, ISO, USP and FDA to ensure that all items that are required to be sterile or endotoxin-free are able to consistently and reliably be sterilized to reduce the chance of introducing or spreading an infectious micro-organism or pyrogens.

Follow the Regulations requirement, use Bioendo ECV is able to operate the endotoxin free validation or pyrogen free validation. More important information is Bioendo ECV no need rubber lid(cap) removal in the heating operation.

 

2. Product Parameter

The potency: 1000 to 10000 EU per vial and 2000 to 10000 EU in a vial.  

 

3. Product Features and Application

In vial with heat resistant stopper (tolerable high temperature up to 360 Celsius degree) and heat resistant label. 

In the procedure of baking or drying, ECV vial’s lid no need to remove. 

Without excipient.  

Endotoxin Challenge Vial  (10ml glass bottle and 2ml of ISO standard 2R glass bottle)

Catalog No.

Endotoxins Level (EU/vial)

Package

ECV1250V

1000-10000

In Vial, 10 Vials/Pack

ECV1250VR

 1000-10000

ISO 2R vial, 10 Vials/Pack

ECV2500V

2000-10000

In Vial, 10 Vials/Pack

ECV2500VR

 2000-10000

ISO 2R vial, 10 Vials/Pack

ECV100000V

50000-200000

In Vial, 10 Vials/Pack

How is the features of Bioendo’s Endotoxin Challenge Vails (Endotoxin Indicator)?

Endotoxin challenge vial, in the operation procedures, the lysate reagent has to match the ECV kit, and no need remove the lit during the baking procedure.


Product detail pictures:

Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures

Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo detail pictures


Related Product Guide:

We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for Factory Free sample Bacterial Endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo , The product will supply to all over the world, such as: Dubai, Spain, Zurich, Our items are widely recognized and trusted by users and can meet continuously developing economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success!
  • This is a honest and trustworthy company, technology and equipment are very advanced and the prodduct is very adequate, there is no worry in the suppliment.
    5 Stars By Meredith from Istanbul - 2018.05.15 10:52
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Georgia from Madrid - 2017.07.28 15:46

    Leave Your Messages

    Related products

    • 2022 Good Quality Rapid Gel Clot Test - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo

      2022 Good Quality Rapid Gel Clot Test - Bioend...

      Bioendo GC Endotoxin Test Kit Bioendo GC Endotoxin Test Kit (Gel Clot Assay)  1. Product Information Bioendo GC Endotoxin Test Kit (Gel Clot Assay) contains 128 Tests/Kit, 400Tests/Kit, 1600Tests/Kit, and 4500 Tests/Kit. And sensitivity of Amebocyte Lysate included by the Kit is 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Kit contains Amebocyte Lysate, CSE and Water for BET. Four kinds of configuration of gel-clot endotoxin assay kit to satisfied the demand. This means yo...

    • OEM China Endotoxin Detection Kit - Endotoxin-free Glass Test Tubes – Bioendo

      OEM China Endotoxin Detection Kit - Endotoxin-...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • 2022 Good Quality TAL assay kit - Mini Dry Heat Incubator – Bioendo

      2022 Good Quality TAL assay kit - Mini Dry Hea...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • High reputation 1000ul Pipette tip box - Mini Dry Heat Incubator – Bioendo

      High reputation 1000ul Pipette tip box - Mini ...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Wholesale Price Endotoxin Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      Wholesale Price Endotoxin Gel Clot Test Kit - ...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

    • OEM/ODM China Kinetic Turbidimetric Method of endotoxin testing - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      OEM/ODM China Kinetic Turbidimetric Method of e...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...