We're proud from the higher client fulfillment and wide acceptance due to our persistent pursuit of high quality both on product and service for Endotoxin Is Produced By, Gel Clot LAL Assay Quick Guide, Endotoxin indicator vial, We sincerely hope to serve you and your business with a good start. If there is anything we can do for You, we shall be more than pleased to do so. Welcome to our factory for visit.
Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo Detail:

Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay)

1. Product Introduction

Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.
The kit contains Lyophilized Amebocyte Lysate, Control Standard Endotoxin, and Water for BET. KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) require a kinetic microplate reader such as ELx808IULALXH or a kinetic tube reader. Kinetic software is also required for calculation of the endotoxin concentration.

2. Product Parameter

Assay Range: 0.005 – 5EU/ml; 0.01 – 10EU/ml

3. Product Application

End-product endotoxin (pyrogen) qualification, Waterfor injection endotoxin assay, raw material endotoxin testing or endotoxinlevel monitoring during manufacturing process for pharmaceutical companies ormedical devices manufacturers.

Note:

Lyophilized Amebocyte Lysate reagent manufactured by Bioendo is made from amebocyte lysate from the horseshoe crab (Tachypleus tridentatus).

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

KT0817

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 128 tests/kit

8 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

8 Reconstitution Buffer, 3.0ml/vial;

4 CSE; 2 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0817S

0.005-5EU/ml,

0.01-10EU/ml

KT0852

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 400 Tests/Kit

8 Lyophilized Amebocyte Lysate, 5.2ml (50 Tests/Vial);

8 Reconstitution Buffer, 6.0ml/vial;

4 CSE; 3 Water for BET, 50ml/vial;

0.01-10EU/ml

KT0852S

0.005-5EU/ml,

0.01-10EU/ml

KT5017

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 800 Tests/Kit

50 Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/vial);

50 Reconstitution Buffer, 3.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5017S

0.005-5EU/ml,

0.01-10EU/ml

KT5052

Bioendo™ KT Endotoxin Test Kit

(Kinetic Turbidimetric Assay), 2500 Tests/Kit

50 Lyophilized Amebocyte Lysate,5.2ml (50 Tests/vial);

50 Reconstitution Buffer, 6.0ml/vial; 10 CSE;

0.01-10EU/ml

KT5052S

0.005-5EU/ml,

0.01-10EU/ml

Product Condition:

The potency of Lyophilized Amebocyte Lysate and Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.


Product detail pictures:

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures

Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo detail pictures


Related Product Guide:

Our company promises all users of the first-class products and the most satisfying post-sale service. We warmly welcome our regular and new customers to join us for Excellent quality Turbidimetric endotoxin assays - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo , The product will supply to all over the world, such as: San Francisco, Brazil, Cambodia, With a wide range, good quality, reasonable prices and stylish designs, our solutions are extensively used in beauty and other industries. Our solutions are widely recognized and trusted by users and can meet continuously changing economic and social needs.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Griselda from Myanmar - 2018.06.05 13:10
    We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Vanessa from Austria - 2017.02.18 15:54

    Leave Your Messages

    Related products

    • Free sample for Bacterial Endotoxin Test Procedure - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Free sample for Bacterial Endotoxin Test Proced...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Low MOQ for Bacterial Endotoxins Test Usp - Control Standard Endotoxin (CSE) – Bioendo

      Low MOQ for Bacterial Endotoxins Test Usp - Co...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Best Price for Endotoxin Indicator For Depyrogenation Usp - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Best Price for Endotoxin Indicator For Depyroge...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Chinese Professional Chromogenic LAL assay - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Chinese Professional Chromogenic LAL assay - B...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...

    • Factory Price For Endotoxin Free Tubes - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Factory Price For Endotoxin Free Tubes - Pyrog...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      Manufacturer for Rapid Gel Clot Test Kit - Gel...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...