Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo


Product Detail

Related Video

Feedback (2)

Bear "Customer first, High quality first" in mind, we perform closely with our consumers and provide them with efficient and experienced services for Control Standard Endotoxin COA, Kinetic chromogenic LAL Assay, Bacterial Endotoxin Test Kinetic Turbidimetric Method, We are looking forward to building positive and beneficial links with the companies around the world. We warmly welcome you to contact us to begin discussions on how we can bring this into being.
Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoid waste. Endotoxin free tubes for the dilution of Lyophilized CSE is necessary. Operation of endotoxin detection use Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule conforms to the national Pharmacopoeia.  

2. Product Parameter

Gel clot assay single test glass ampoule.

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml, 0.5EU/ml. 

3.Product Feature and Application

Single step endotoxin detection,

Normal water bath or dry heat incubator is available for the gel clot method. 

Suitable for end-product endotoxin testing before product released.

Product sensitivity standardized according to the China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog No.

Sensitivity EU/ml

Description

Kit Contents

GS010030

0.03

Bioendo Gel Clot Endotoxin Test Kit, Single Test in Ampoule.

10 tests per pack

GS010060

0.06

GS010125

0.125

GS010250

0.25

GS010500

0.5

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why the most selected gel clot assay kit G01:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a ampoule for one step reduce the risk of contamination.

3. Gel clot assay single test glass ampoule no need sophisticated microplate reader.

4. Saving endotoxin free tube when using G01 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW02, TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10A.

Product detail pictures:

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures


Related Product Guide:

The corporate keeps towards the operation concept "scientific administration, superior quality and performance primacy, client supreme for Manufacturer for Rapid Gel Clot Test Kit - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo , The product will supply to all over the world, such as: Lisbon, Honduras, Cambodia, Our company has always insisted on the business principle of "Quality, Honest, and Customer First" by which we have won the trust of clients both from at home and abroad. If you are interested in our solutions, you should do not hesitate to contact us for further information.
  • This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Eleanore from Japan - 2018.11.04 10:32
    The factory technical staff gave us a lot of good advice in the cooperation process, this is very good, we are very grateful.
    5 Stars By Tony from Kenya - 2018.12.11 11:26

    Leave Your Messages

    Related products

    • Factory Cheap Hot LAL test endotoxin - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Factory Cheap Hot LAL test endotoxin - Endotox...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • Manufacturer of Dry Heat Sterilization Validation – Mini Dry Heat Incubator – Bioendo

      Manufacturer of Dry Heat Sterilization Validati...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Hot-selling Pipette tip supplier - Eight-channel Mechanical Pipette – Bioendo

      Hot-selling Pipette tip supplier - Eight-chann...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...

    • Lowest Price for Bacteria That Produce Endotoxins - Pyrogen-free Pipette tips and Consumables – Bioendo

      Lowest Price for Bacteria That Produce Endotoxi...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Factory wholesale Kinetic chromogenic LAL test - Endpoint Chromogenic Kit EC64405 – Bioendo

      Factory wholesale Kinetic chromogenic LAL test ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Factory Cheap Hot LAL testing medical device – (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) – Bioendo

      Factory Cheap Hot LAL testing medical device &#...

      Fungi(1,3)-β-D-glucan Assay Kit Product information: (1-3)-β-D-Glucan Detection Kit (Kinetic Chromogenic Method) measures levels of (1-3)-β-D-Glucan by kinetic chromogenic method. The assay is based upon a modification factor G pathway of the Amebocyte Lysate (AL). (1-3)-β-D-Glucan activates Factor G, the activated Factor G converts the inactive proclotting enzyme to the active clotting enzyme, which in turn cleaves pNA from the chromogenic peptide substrate. pNA is a chromophore that absorb...