Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo


Product Detail

Related Video

Feedback (2)

So that you can finest fulfill client's demands, all of our operations are strictly performed in line with our motto "High Excellent, Competitive Price, Fast Service" for Rapid Endotoxin Detection, Rapid Gel Clot Test Kit, Turbidimetric LAL assay, For anyone who is intrigued in almost any of our solutions or want to talk about a custom made purchase, make sure you sense free of charge to get in touch with us.
Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo Detail:

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

1. Product Information

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin concentration of test sample could be calculated based on a standard curve.

2. Product parameter

Sensitivity Range: 0.01-0.1 EU/ml, matching assay time is about 46 minutes

                              0.1-1 EU/ml, matching assay time is about 16 minutes. 

3. Product Features and Application

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into the mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. Yellow color develops if test sample contains endotoxin. Then use regular spectrophotometer or plate reader to read the absorbance at 405nm. End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is suitable for all kinds of biomedical samples such as protein, vaccine, plasmid, DNA, RNA endotoxin assay. 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

(EU/ml)

EC64405

 

Bioendo™ EC Endotoxin Test Kit (End-point Chromogenic Assay),

64 Tests/Kit

 

2 Lyophilized Amebocyte Lysate, 1.7ml/vial;

2 Water for BET, 50ml/vial;  

2 CSE;

4 Chromogenic Substrate, 1.7ml/vial;

0.1 – 1 EU/ml

EC64405S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/m

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC64405 and EC64405S kit analysis the quantitative endotoxin results through regular microplate reader. 

End point chromogenic endotoxin test kit series:

Endotoxin Free Tube

Pyrogen Free Tips

Pyrogen Free Microplates

Regular Microplate reader

Matched Control standard endotoxin (CSE10V)

BET water use for reconstitution. 

 



Product detail pictures:

Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures


Related Product Guide:

Like a result of ours specialty and repair consciousness, our enterprise has won a superb popularity amid buyers everywhere in the environment for Excellent quality Toxinsensor Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo , The product will supply to all over the world, such as: Orlando, Albania, Norwegian, So We also continuously function. we, focuse on high quality, and are conscious of the importance of environmental protection, most of the merchandise are pollution-free, environmentally friendly solutions, reuse on the solution. We've Updated our catalog, which introduces our organization. n detail and covers the primary products we provide at present, You may also visit our web-site, which involves our most recent product line. We look forward to reactivating our company connection.
  • The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Laurel from Greece - 2017.09.16 13:44
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Candance from Congo - 2018.05.22 12:13

    Leave Your Messages

    Related products

    • Lowest Price for Bacteria That Produce Endotoxins - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Lowest Price for Bacteria That Produce Endotoxi...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • OEM China Endotoxin Detection Kit - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      OEM China Endotoxin Detection Kit - Pyrogen-fr...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Bottom price Endotoxin free test tube - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      Bottom price Endotoxin free test tube - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • 2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Multi-test Vial G52 – Bioendo

      2022 Good Quality Rapid Gel Clot Test - Gel Cl...

      Gel Clot Method Lyophilized Amebocyte Lysate Multi-test Vial G52 series 1. Product Information Gel Clot method Lyophilized Amebocyte Lysate Multi-test Vial is the Lyophilized Amebocyte Lysate reagent which select and use gel clot technique to detect endotoxin or pyrogen. As the widespread method, gel-clot test for endotoxin is simple and does not require specific and expensive instrument. Bioendo provides Gel Clot Lyophilized Amebocyte Lysate reagent in 5.2ml per vial. 2. Product Parameter...

    • Hot New Products LAL endotoxin assay - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Hot New Products LAL endotoxin assay - Pyrogen...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • China wholesale Chromogenic endotoxin detection - Endpoint Chromogenic Kit EC80545 – Bioendo

      China wholesale Chromogenic endotoxin detection...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...