We offer great strength in quality and development,merchandising,sales and marketing and operation for Bacterial Endotoxin Test Usp Limit, TAL test, Application Of LAL Test, At our firm with good quality initially as our motto, we manufacture merchandise that are entirely made in Japan, from materials procurement to processing. This enables them for being used with confident peace of mind.
Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo Detail:

 Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay)

The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit meets the requirements of the rules of Bacterial Endotoxin Test in Pharmacopoeia. Each test requires only the 25μL sample for test and 25μL of lysate reagent. The testing principle is the same as that of the traditional kinetic chromogenic method for endotoxin detection. It has strong anti-interference ability and is very suitable for endotoxins quantitative detection in parenteral drugs, vaccines, antibodies, biological preparations and so on.

Typical users:

Pharmaceutical manufacturers, medical devices manufacturers, scientific research institutions.

Ø Less dosage of sample for test , and each test only needs 25μL of samples for testing.
Ø Adopting the pharmacopoeia-approved kinetic chromogenic method technology which can meet the requirements of GMP for data integrity and traceability.
Ø High sensitivity, up to 0.005EU/ml.
Ø Strong anti-interference ability, does not require coagulogen to form a gel, and accurately quantifies bacterial endotoxins based on the color reaction.
Ø Easy to operate, complete 96 tests at one time, and the system automatically detects and analyzes in one step.
Ø High cost-effective, higher performance.
Ø Supporting 8-well plate for micro-detection

 

Technical Parameters: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

What is the main feature of new Bioendo microKC kit?

Each test requires only the 25μL sample for test and 25μL of lysate reagent. Provide the professional solution that is very friendly in terms of resource utilization. 

 

Endotoxin free microplates MPMC96: the strip is individual wrap, 8 wells a strips, provide economical solution for the micro kinetic chromogenic assay.
Kinetic microplate reader Elx808 or others Elx808 series.

Pyrogen free microplate

 


Product detail pictures:

Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures


Related Product Guide:

To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for Chinese Professional Chromogenic LAL assay - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo , The product will supply to all over the world, such as: Luxemburg, Orlando, Hungary, All the employees in factory, store, and office are struggling for one common goal to provide better quality and service. Real business is to get win-win situation. We would like to provide more support for customers. Welcome all nice buyers to communicate details of our products with us!
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Georgia from Luxembourg - 2018.11.02 11:11
    This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Roxanne from Albania - 2018.03.03 13:09

    Leave Your Messages

    Related products

    • Wholesale depyrogenation is a 3-log reduction in endotoxin content - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Wholesale depyrogenation is a 3-log reduction i...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • High Quality for Endotoxin free reagent reservoir - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      High Quality for Endotoxin free reagent reservo...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Factory Supply Endotoxin Free Water - Pyrogen-free Pipette tips and Consumables – Bioendo

      Factory Supply Endotoxin Free Water - Pyrogen-...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Wholesale Price BET Water - Rapid Gel Clot 10 Samples Kit – Bioendo

      Wholesale Price BET Water - Rapid Gel Clot 10 ...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • China wholesale LAL gel clot - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      China wholesale LAL gel clot - Gel Clot Lyophi...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoules, you could add samples to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to av...

    • PriceList for Kinetic Turbidimetric TAL Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      PriceList for Kinetic Turbidimetric TAL Kit - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...