End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling)

1. Product Information

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin concentration of test sample could be calculated based on a standard curve.

2. Product parameter

Sensitivity Range: 0.01-0.1 EU/ml, matching assay time is about 46 minutes

                              0.1-1 EU/ml, matching assay time is about 16 minutes. 

3. Product Features and Application

End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into the mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. Yellow color develops if test sample contains endotoxin. Then use regular spectrophotometer or plate reader to read the absorbance at 405nm. End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is suitable for all kinds of biomedical samples such as protein, vaccine, plasmid, DNA, RNA endotoxin assay. 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

(EU/ml)

EC64405

 

Bioendo™ EC Endotoxin Test Kit (End-point Chromogenic Assay),

64 Tests/Kit

 

2 Lyophilized Amebocyte Lysate, 1.7ml/vial;

2 Water for BET, 50ml/vial;  

2 CSE;

4 Chromogenic Substrate, 1.7ml/vial;

0.1 – 1 EU/ml

EC64405S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/m

Product Condition:

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC64405 and EC64405S kit analysis the quantitative endotoxin results through regular microplate reader. 

End point chromogenic endotoxin test kit series:

Endotoxin Free Tube

Pyrogen Free Tips

Pyrogen Free Microplates

Regular Microplate reader

Matched Control standard endotoxin (CSE10V)

BET water use for reconstitution. 

 



Product detail pictures:

China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures

China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo detail pictures


Related Product Guide:

With a sound business credit, excellent after-sales service and modern manufacturing facilities, we have earned an excellent reputation among our customers across the world for China Cheap price Chromogenic endotoxin assay - Endpoint Chromogenic Kit EC64405 – Bioendo , The product will supply to all over the world, such as: Costa rica, Spain, Hanover, Our company covers an area of 20, 000 square meters. We have more than 200 workers, professional technical team, 15 years' experience, exquisite workmanship, stable and reliable quality, competitive price and sufficient production capacity, this is how we make our customers stronger. If you have any inquiry, please do not hesitate to contact us.
  • On this website, product categories is clear and rich, I can find the product I want very quickly and easily, this is really very good!
    5 Stars By Monica from Tanzania - 2018.09.21 11:01
    The customer service staff's attitude is very sincere and the reply is timely and very detailed, this is very helpful for our deal,thank you.
    5 Stars By Elsa from Jersey - 2017.09.30 16:36

    Leave Your Messages

    Related products

    • Top Suppliers Endotoxin LAL Test Kit - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Top Suppliers Endotoxin LAL Test Kit - Pyrogen...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog ...

    • 2022 China New Design LAL chromogenic test - Endpoint Chromogenic Kit EC64405 – Bioendo

      2022 China New Design LAL chromogenic test - E...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Bottom price 250ul Pipette tip box - Rapid Gel Clot single test kit – Bioendo

      Bottom price 250ul Pipette tip box - Rapid Gel...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Factory Cheap Hot Chromogenic LAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Factory Cheap Hot Chromogenic LAL test - Micro...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Well-designed Bacterial Endotoxin Calculation - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Well-designed Bacterial Endotoxin Calculation -...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Hot New Products Chromogenic endotoxin test - Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) – Bioendo

      Hot New Products Chromogenic endotoxin test - ...

      Bioendo KC Endotoxin Test Kit (Kinetic Chromogenic Assay) 1. Product Information In Bioendo KC Endotoxin Test Kit, Amebocyte Lysate is co-lyophilized with chromogenic substrate. Therefore, bacterial endotoxin could be quantified based on the chromogenic reaction. The assay is strong resistance to interference, and has advantages of kinetic turbidimetric and end-point chromogenic method. Bioendo Endotoxin Test Kit contains Chromogenic Amebocyte Lysate, Reconstitution Buffer, CSE, Water for BE...