Bear "Customer first, Quality first" in mind, we work closely with our customers and provide them with efficient and professional services for Dry Heat Sterilizer Validation, Bacteria That Produce Endotoxins, LAL test kit, Sincerely hope we are growing up together with our prospects all over the environment.
Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo Detail:

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling)

1. Product Information

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum absorbance at 545nm. A regular spectrophotometer or microplate reader is required for the assay. The purple items are proportional to endotoxin concentration. Then endotoxin testing result is quantitative analysis. 

2. Product Parameter

Sensitivity Range: 0.01-0.1EU/ml (assay time about 46 minutes)

                             0.1-1.0EU/ml (assay time about 16 minutes)

3. Product Features and Application

Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) is intended for use in the In Vitro detection and quantitation of gram-negative bacterial endotoxins. The colorless artificial peptide substrate solution is added into Lyophilized Amebocyte Lysate, and then test specimen mixture. If specimen contains endotoxin, color of specimen mixture changes. The absorbance is related to the endotoxin concentration. Therefore the endotoxn levels in specimen mixture can be claculated against a standard curve. Standard spectrophotometer with 540 – 545nm filter is enough to quantify endotoxin with our EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling).

 

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

EC80545

Bioendo™ EC Endotoxin Test Kit

(End-point Chromogenic Assay,

Diazo Coupling),

80 Tests/Kit

5 Lyophilized Amebocyte Lysate, 1.7ml/vial;

4 Water for BET, 50ml/vial;

5 CSE;

5 Chromogenic Substrate, 1.7ml/vial;

5 Diazo Reagent 1, 10ml/vial;

5 Diazo Reagent 2, 10ml /vial;

5 Diazo Reagent 3, 10ml/vial;

0.1 – 1 EU/ml

EC80545S

0.01 – 0.1 EU/ml;

0.1 – 1 EU/ml

Product Conditions

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

 

Does the End point endotoxin test kit need sophisticated microplate reader?

Bioendo EC80545 and EC80545S, can read by regular spectrophotometer. 

Bioendo End point chromogenic endotoxin test kit series:
Endotoxin Free Tube
Pyrogen Free Tips
Pyrogen Free Microplates
normal Microplate reader
Water Bath or Dry Heat Incubator 

Product detail pictures:

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures

Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo detail pictures


Related Product Guide:

As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for Best quality Micro kinetic chromogenic endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo , The product will supply to all over the world, such as: Ecuador, venezuela, Philippines, Besides there are also experienced production and management , advanced production equipment to assure our quality and delivery time , our company pursues the principle of good faith, high-quality and high-efficiency. We guarantee that our company will try our best to reduce customer purchase cost, shorten the period of purchase, stable solutions quality, increase customers' satisfaction and achieve win-win situation .
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Ingrid from Eindhoven - 2017.01.11 17:15
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Ivy from Georgia - 2018.03.03 13:09

    Leave Your Messages

    Related products

    • Factory wholesale TAL Reagent Water - Rapid Gel Clot 10 Samples Kit – Bioendo

      Factory wholesale TAL Reagent Water - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Lowest Price for Bacteria That Produce Endotoxins - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Lowest Price for Bacteria That Produce Endotoxi...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...

    • 2022 Good Quality Rapid Gel Clot Test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo

      2022 Good Quality Rapid Gel Clot Test - Gel Cl...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoi...

    • Best Price on Endotoxin Detection Kit Sigma - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Best Price on Endotoxin Detection Kit Sigma - ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Best-Selling Endotoxin Lipopolysaccharide - Control Standard Endotoxin (CSE) – Bioendo

      Best-Selling Endotoxin Lipopolysaccharide - Co...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Wholesale Price China LAL test for pyrogens - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      Wholesale Price China LAL test for pyrogens - ...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...