Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo


Product Detail

Related Video

Feedback (2)

We know that we only thrive if we can guarantee our combined rate competiveness and good quality advantageous at the same time for LAL endotoxin, Control Standard Endotoxin COA, endotoxin detection, Since the manufacturing facility founded, we have now committed on the progress of new products. While using the social and economic pace, we are going to continue to carry forward the spirit of "high high-quality, efficiency, innovation, integrity", and persist with the operating principle of "credit to start with, customer initially, top quality excellent". We'll make a amazing long run in hair output with our companions.
Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo Detail:

 Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay)

The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit meets the requirements of the rules of Bacterial Endotoxin Test in Pharmacopoeia. Each test requires only the 25μL sample for test and 25μL of lysate reagent. The testing principle is the same as that of the traditional kinetic chromogenic method for endotoxin detection. It has strong anti-interference ability and is very suitable for endotoxins quantitative detection in parenteral drugs, vaccines, antibodies, biological preparations and so on.

Typical users:

Pharmaceutical manufacturers, medical devices manufacturers, scientific research institutions.

Ø Less dosage of sample for test , and each test only needs 25μL of samples for testing.
Ø Adopting the pharmacopoeia-approved kinetic chromogenic method technology which can meet the requirements of GMP for data integrity and traceability.
Ø High sensitivity, up to 0.005EU/ml.
Ø Strong anti-interference ability, does not require coagulogen to form a gel, and accurately quantifies bacterial endotoxins based on the color reaction.
Ø Easy to operate, complete 96 tests at one time, and the system automatically detects and analyzes in one step.
Ø High cost-effective, higher performance.
Ø Supporting 8-well plate for micro-detection

 

Technical Parameters: 

Catalog No.

Description

Kit Contents

Sensitivity EU/ml

MKC0505VS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/Vial);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505V

0.01 to 10EU/ml

MKC0505AS

Bioendo™ KC Endotoxin Test Kit (Micro Kinetic Chromogenic Assay), 90 Tests/Kit

5 Chromogenic Amebocyte Lysate, 0.5ml (18 Tests/ampoule);

5 Reconstitution Buffer, 2.0ml/vial; 

0.005 to 5EU/ml

MKC0505A

0.01 to 10EU/ml

MPMC96

8 wells per strip

96 wells per microplate, 12pcs detachable strips.

 

What is the main feature of new Bioendo microKC kit?

Each test requires only the 25μL sample for test and 25μL of lysate reagent. Provide the professional solution that is very friendly in terms of resource utilization. 

 

Endotoxin free microplates MPMC96: the strip is individual wrap, 8 wells a strips, provide economical solution for the micro kinetic chromogenic assay.
Kinetic microplate reader Elx808 or others Elx808 series.

Pyrogen free microplate

 


Product detail pictures:

Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures

Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo detail pictures


Related Product Guide:

It truly is a great way to improve our merchandise and repair. Our mission should be to create imaginative products to prospects with a excellent knowledge for Best quality LAL chromogenic detection - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo , The product will supply to all over the world, such as: Juventus, Bolivia, Mozambique, As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality items we offer, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We are confident that we'll share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.
  • The factory technical staff not only have high level of technology, their English level is also very good, this is a great help to technology communication.
    5 Stars By Phoebe from Puerto Rico - 2018.09.23 17:37
    This supplier stick to the principle of "Quality first, Honesty as base", it is absolutely to be trust.
    5 Stars By Penelope from Cape Town - 2017.02.18 15:54

    Leave Your Messages

    Related products

    • Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo

      Special Design for Bacterial Endotoxin Test Met...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • Online Exporter Endotoxin Detection System - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Online Exporter Endotoxin Detection System - P...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Best quality Kinetic Turbidimetric LAL Test - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Best quality Kinetic Turbidimetric LAL Test - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Factory source Advantage Of LAL Test - Rapid Gel Clot single test kit – Bioendo

      Factory source Advantage Of LAL Test - Rapid G...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • New Delivery for Biochemical Nature Of Bacterial Endotoxin Is - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      New Delivery for Biochemical Nature Of Bacteria...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...