2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo


Product Detail

Related Video

Feedback (2)

With this motto in mind, we've turn into one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for Bacterial Endotoxin Limit For API, Bacterial Endotoxin Limit For API, Endotoxin free tip box, Please feel absolutely free to speak to us for organization. nd we believe we will share the best trading practical experience with all our merchants.
2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo Detail:

Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule

1. Product Information

Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in glass ampoule, you could add sample to the glass ampoules directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many tests use each time to avoid waste. Endotoxin free tubes for the dilution of Lyophilized CSE is necessary. Operation of endotoxin detection use Bioendo Gel Clot Lyophilized Amebocyte Lysate Single Test in ampoule conforms to the USP, the EP. 

2. Product Parameter

Gel clot assay single test glass ampoule.

Sensitivities:  0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25 EU/ml

3.Product Feature and Application

Single step endotoxin detection,

without expensive endotoxin assay instrument.

Suitable for end-product endotoxin testing before product released.

Product sensitivity standardized according to US Pharmacopoeia criterion and China Pharmacopoeia criterion.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from lysate of amebocytes (white blood cells) from the horseshoe crab.

Catalog No.

Sensitivity EU/ml

Description

Kit Contents

GS44010030

0.03

Bioendo Gel Clot Endotoxin Test Kit, (Single Test in Ampoule, 44Tests/Kit),

44 Gel Clot Lyophilized Amebocyte Lysate;

1 CSE 10A;

5 Water for BET , 2ml/vial

GS44010060

0.06

GS44010125

0.125

GS44010250

0.25

GS44010500

0.5

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis, MSDS.

Why the most selected gel clot assay kit GS44:

1. The most economical and commonly used test reagent for endotoxin detection.

2. Single test in a vial for one stepping reduce the risk of contamination.

3. Gel clot assay single test glass vial no need sophisticated microplate reader.

4. Saving endotoxin free tube when using GS44 series to test endotoxins in the procedure of endotoxin test assay’s operation.

Related products in the endotoxin test assay:
Water for Bacterial Endotoxins Test (BET),  Recommend TRW02, TRW50 or TRW100
Endotoxin free glass tube ( dilution tube ),  Recommend T1310018
Pyrogen free tips,  Recommend PT25096 or PT100096
Pipettor, Recommend PSB0220
Test Tube Rack,
Incubation Instrument (Water Bath or Dry Heat Incubator ), Recommend Dry Heat Incubator TAL-M2
Vortex Mixter, Recommend VXH.
Control Standard Endotoxin, CSE10A.

Product detail pictures:

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures

2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo detail pictures


Related Product Guide:

In an effort to finest meet up with client's requirements, all of our operations are strictly performed in line with our motto "High High quality, Competitive Rate, Fast Service" for 2022 China New Design Gel Clot Method - Gel Clot Lyophilized Amebocyte Lysate Single Test in Ampoule – Bioendo , The product will supply to all over the world, such as: Lahore, Bogota, America, We confirm to public, cooperation, win-win situation as our principle, adhere to the philosophy of make a living by quality, keep developing by honesty , sincerely hope to build up a good relationship with more and more customers and friends, to achieve a win-win situation and common prosperity.
  • Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Honey from Indonesia - 2017.09.26 12:12
    We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Jessie from Hungary - 2018.05.15 10:52

    Leave Your Messages

    Related products

    • Factory wholesale Endotoxin Activity Assay - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo

      Factory wholesale Endotoxin Activity Assay - L...

      LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water )  1. Product Information LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET )is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could...

    • Wholesale Price Micro kinetic chromogenic endotoxin assay - Endpoint Chromogenic Kit EC80545 – Bioendo

      Wholesale Price Micro kinetic chromogenic endot...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Professional China LAL assay - Mini Dry Heat Incubator – Bioendo

      Professional China LAL assay - Mini Dry Heat I...

      Dry heat incubator single module 1. Product information  The Mini Dry Heat Incubator is a micro-processor controlled heating block with semi conductor heating technology.It adapts onboard use, smart, light and convenient for movement, suit for any kind of occasions. Especially good for the incubation of the gel clot LAL assay, LAL chromogenic endpoint assay incubation. 2. Product features 1. Unique designed. Smart and light, convenient movement, suit for various occasions. 2. LCD simultaneou...

    • Factory selling Bacterial Endotoxin Limit For API - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Factory selling Bacterial Endotoxin Limit For A...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Low price for Pipettor tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Low price for Pipettor tip box - Rapid Gel Clo...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • 100% Original 200ul Pipette tip - Eight-channel Mechanical Pipette – Bioendo

      100% Original 200ul Pipette tip - Eight-channe...

      Eight-Channel Mechanical Pipettor 1. Product information All multi-channel mechanical pipettor have been quality tested according to ISO8655-2:2002 with calibration certificate. The quality control involves gravimetric testing of each pipette with distilled water at 22℃. The multichannel mechanical pipettor is idea for the detectionof bacterial endotoxin lal endotoxin testing by kinetic turbidimetric andkinetic chromogenic method. - Eight-Channel Mechanical Pipettor is available for stand...