100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo


Product Detail

Related Video

Feedback (2)

The corporate keeps towards the operation concept "scientific administration, superior quality and performance primacy, client supreme for Bacterial Endotoxin Test As Per Indian Pharmacopoeia, LAL Test, Kinetic chromogenic TAL Assay kit, We are always looking forward to forming successful business relationships with new clients around the world.
100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo Detail:

Dry Heat Incubator

1. Product description:

Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

2. Product features

1, LCD display, simple interface.

2, high heating speed, uniformheating, accurate temperature control, high stability, low energy consumptionand no noise.

3, Built in temperature calibrationfunction, automatic fault detection and buzzer alarm function.

4, Built in over-temperatureprotection device, safe and reliable use, prolong the service life of themachine.

5, product design, compact and tight,small occupied space, freer and easier.

6, Various blocks for convenientreplacement, cleaning and disinfection.

7,It Can achieve two independentheating modules, thermostats, unique combo designed to meet the needs of moreexperimental.

dry bath double control, dry incubator doublemodule, limulus polyphemus blue blood, tal kinetic chromogenic method, talendotoxin kit

Product Name & Descriptions

TAL-M2 Dry heat incubator

(single heating module);

One modular total 60 holes for mass test in pharmaceuticals application.

Temperature control Range Ambient+5℃ ~ 150℃
Temperature setting range Ambient+5℃ ~ 150℃
Temperature rising time ≤ 30min (from 20℃ rise to 150℃), rise to 37deg C in about 60s.
Temperature Stability @100~150℃ ≤±1℃
Temperature Stability @40~100℃ ≤±0.5℃
Temperature Uniformity @40℃ ±0.3℃
Modular temperature uniformity ±0.5℃
Displayed Temperature Precision 0.1℃
Temperature Control time 99h59min
Fuse protector 250v, 3A/6A, Φ5×20
Highest Temperature 150℃
Power supply AC220V/AC110V, 50/60Hz, 400W
Dimension D260*W220*H95mm

 


Product detail pictures:

100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo detail pictures

100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo detail pictures

100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

With our excellent management, strong technical capability and strict quality control system, we continue to provide our clients with reliable quality, reasonable prices and excellent services. We aim at becoming one of your most reliable partners and earning your satisfaction for 100% Original 200ul Pipette tip - Compact Modular Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Burundi, Paraguay, Sacramento, Honest to every customers are our requested! First-class serve, best quality, best price and fastest delivery date is our advantage! Give every customers good serve is our tenet! This makes our company get the favour of customers and support! Welcome all over the world customers send us enquiry and looking forward your good co-operation !Please your inquiry for more details or request for dealership in selected regions.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Maria from Egypt - 2017.09.09 10:18
    Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Merry from Azerbaijan - 2017.06.16 18:23

    Leave Your Messages

    Related products

    • Hot sale Endpoint Chromogenic Endotoxin test kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Hot sale Endpoint Chromogenic Endotoxin test ki...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • New Arrival China Gel Clot Endotoxin Test - Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      New Arrival China Gel Clot Endotoxin Test - Ge...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...

    • Cheap PriceList for Endosafe LAL Kit - Compact Modular Dry Heat Incubator – Bioendo

      Cheap PriceList for Endosafe LAL Kit - Compact...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • High definition Control Standard Endotoxin Preparation - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      High definition Control Standard Endotoxin Prep...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      Wholesale Price BET Water - Kinetic Incubating...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Chinese Professional LAL test kit price - Rapid Gel Clot 10 Samples Kit – Bioendo

      Chinese Professional LAL test kit price - Rapi...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...