Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo


Product Detail

Related Video

Feedback (2)

With our rich experience and considerate services, we have been recognized as a reliable supplier for many international buyers for Endotoxin Determination, Endotoxin LAL Method, Endotoxin Free Tube, Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us!
Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo Detail:

Kinetic Incubating Microplate Reader

1. Product information

Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be scaled up toautomatic performance.

2. Instrument parameters

- wavelength range of 340-900 nm, suitable for ultraviolet and visible light detection.

- 6 filter wheel, standard configuration with 5 filters (340,405, 490, 540 and 630 nm).

- temperature control range: room temperature+5℃ to 50℃

- standard curve linear correlation coefficient: |r|≥0.99

- assay repeatability: CV≤5%

- 96 tests per plate

3.  Application range:

- Bacterial endotoxin (pyrogen) assay of drugs, vaccines, Water for Injection medical devices, infusion, transfusion related devices dialysate,dialysis water endotoxin testing cell suspension, cell culture media, cell culture related products recombinant protein, nucleic acid and other molecular biological products

-Endotoxin level monitoring during production: pharmaceutical raw materials, intermediate products, end product endotoxin daily monitoring.

-Clinical diagnostic of sepsis and invasive fungi disease:plasma, serum, urine, cerebrospinal fluid endotoxin and (1,3)-beta-D-glucandetection.

Catalog No.

Description

KPR808IULAL

Kinetic incubating microplate reader Elx808  for Endotoxin and ß-glucan detection

20180903103214_47978

Please contact sales@houshiji.com to order the LAL reagents endotoxin detection kit.

There is no minimal order volume required.

The price depends on the order quantity. We provide distributor discount for our partners.

Bioendo provide professional transport services for sophisticated instruments to make sure safety international transportation.

 

Kinetic microplate incubating reader +

Quantitative Lysate reagent +

Pyrogen free microplate +

Pyrogen free tips.


Product detail pictures:

Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures

Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo detail pictures


Related Product Guide:

Fast and good quotations, informed advisers to help you choose the correct product that suits all your needs, a short production time, responsible quality control and different services for paying and shipping affairs for Wholesale Price BET Water - Kinetic Incubating Microplate Reader ELX808IULALXH – Bioendo , The product will supply to all over the world, such as: Islamabad, Nigeria, Surabaya, With a wide range, good quality, reasonable prices and stylish designs, our products are extensively used in this field and other industries. We welcome new and old customers from all walks of life to contact us for future business relationships and achieving mutual success! We welcome customers, business associations and friends from all parts of the world to contact us and seek cooperation for mutual benefits.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Laurel from Ireland - 2017.03.08 14:45
    This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
    5 Stars By Claire from Sudan - 2017.11.01 17:04

    Leave Your Messages

    Related products

    • OEM/ODM China Kinetic Chromogenic Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      OEM/ODM China Kinetic Chromogenic Endotoxin Ass...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Best Price for Endotoxin Indicator For Depyrogenation Usp - Endotoxin-free Glass Test Tubes – Bioendo

      Best Price for Endotoxin Indicator For Depyroge...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...

    • 2022 wholesale price Chromogenic LAL test - Endpoint Chromogenic Kit EC64405 – Bioendo

      2022 wholesale price Chromogenic LAL test - En...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Hot-selling Pipette tip supplier - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot-selling Pipette tip supplier - Rapid Gel C...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Manufacturing Companies for Bacteria Endotoxin Test - Depyrogenated Sample Bottles ( Endotoxin Free ) – Bioendo

      Manufacturing Companies for Bacteria Endotoxin ...

      Depyrogenated Sample Container 1. Product information We offer various of low endotoxin, pyrogen free accessories products,includes Water for Bacterial Endotoxins Test, pyrogen-free test tubes, pyrogen-free pipettor tips, microplates and sample bottles for your conveniences. High quality depyrogenated low endotoxin pyrogen free products insure the success of your experiments. Depyrogenated (Endotoxin Free) Sample container(endotoxin free bottle, pyrogen free bottle, pyrogen free sample bot...

    • Factory For Bacterial Endotoxin Test Usp Chapter - Control Standard Endotoxin (CSE) – Bioendo

      Factory For Bacterial Endotoxin Test Usp Chapte...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...