Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo


Product Detail

Related Video

Feedback (2)

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Bacterial Endotoxin Test As Per Indian Pharmacopoeia, Rapid Gel Clot Test Kit, Bacterial Endotoxin Test Gel Clot Method Sop, As a leading manufacture and exporter, we appreciate a great status inside the international markets, especially in America and Europe, because of our top high-quality and sensible charges.
Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo Detail:

Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit)
1. Product Information

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedures are very convenient, additional experimental equipment are required. It is a convenient and rapid way to detect endotoxin in especial suitable for water or dialysate.

20190819091605_48802

2. Product Parameter

Sensitivity Range: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5EU/ml

10 sample tests in the kit. 

Assay time: less than 30 minutes

3. Product Application

Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate as well as do quickly endotoxin detection in life science research.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Description

Kit Contents

Sensitivity

EU/ml

Reaction Time

minutes

RG10025003

BioendoTM Rapid Gel Clot Endotoxin Assay Kit, 10 Samples Kit

10 SPL Tubes;

10 PPC Tubes;

10 Endotoxin-free Sample Bottles;

10 Packs of (3pcs Transfer Pipettes)

0.03

≤60

RG10025006

0.06

≤60

RG100250125

0.125

≤45

RG10025025

0.25

≤30

RG10025050

0.5

≤30

Kit configuration: 
Bioendo Rapid Gel Clot Endotoxin Assay Kit contains: 
10 SPL Tube, 10 PPC Tube, 10 Endotoxin-free Sample Bottle, 10 Pack of Transfer Pipette 3 pieces.
Simple and convenient procedure in the dilution of control standard endotoxin. Endotoxin free sample container and pyrogen free transfer pipette is required, Sophisticated instruments are required, recommend Bioendo Dry heat incubator TAL-MT use in the procedure of incubation.   

Product detail pictures:

Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures

Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo detail pictures


Related Product Guide:

"Based on domestic market and expand overseas business" is our improvement strategy for Top Suppliers Dry Heat Sterilizer Validation - Rapid Gel Clot 10 Samples Kit – Bioendo , The product will supply to all over the world, such as: Austria, Oslo, Saudi Arabia, With the development and enlargement of mass clients abroad, now we have set up cooperative relationships with many major brands. We have our own factory and also have many reliable and well-cooperated factories in the field. Adhering to the "quality first, customer first, We are provideing high-quality, low-cost products and first-class service to customers. We sincerely hope to establish business relationship with customers from all over the world on the basis of quality, mutually benefit. We welcome OEM projects and designs.
  • We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Lilith from Guyana - 2018.07.27 12:26
    Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
    5 Stars By Rose from Doha - 2018.09.21 11:01

    Leave Your Messages

    Related products

    • Bottom price 250ul Pipette tip box - Rapid Gel Clot 10 Samples Kit – Bioendo

      Bottom price 250ul Pipette tip box - Rapid Gel...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Chinese Professional endotoxin removal - EtEraser™ SE Endotoxin Removal Kit – Bioendo

      Chinese Professional endotoxin removal - EtEra...

      EtEraser™ SE Endotoxin Removal Kit 1. Product information Lipopolysaccharide (LPS) is a bacterial endotoxin and a majorconstituent of the cell walls of gramnegative bacteria. Recombinant proteinfrom E.coli usually contains high level of endotoxins. The removal of theseendotoxins is highly necessary for downstream processes. EtEraser SE Endotoxin Removal kit are designedto remove endotoxin contamination from aqueous solutions. The kits containendotoxin removal resin binds to reduce endotoxin...

    • One of Hottest for Bacterial Endotoxin Test In Pharmaceutical - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      One of Hottest for Bacterial Endotoxin Test In ...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • Manufacturer of Endotoxin LAL Testing - Control Standard Endotoxin (CSE) – Bioendo

      Manufacturer of Endotoxin LAL Testing - Contro...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • Reasonable price Depyrogenated tips - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      Reasonable price Depyrogenated tips - Kinetic ...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • PriceList for Endotoxin Gel Clot Assay – Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial – Bioendo

      PriceList for Endotoxin Gel Clot Assay – ...

      Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial 1. Product Information Gel Clot Lyophilized Amebocyte Lysate Single Test in Vial Contain endotoxin-specific Amebocyte Lysate which includes beta-glucan inhibitor in the formulation and will not react to beta-glucan. For our Single Test in Vial, you could add sample to the vial directly. This means you don’t need to reconstitute Amebocyte Lysate at first, and you will decide how many vials use each time to avoid waste. Endotoxin free t...