We take "customer-friendly, quality-oriented, integrative, innovative" as objectives. "Truth and honesty" is our management ideal for Endotoxin Detection Methods, Endotoxin Indicator For Depyrogenation Usp, Pyrogen free tip box, You should send us your specifications and requirements, or feel totally free to speak to us with any questions or inquiries that you may have.
Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo Detail:

Endotoxin-free Glass Test Tubes

 

1. Product Information

Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used for kinetic tube reader.

 

2. Product Parameter

Endotoxin level ≤0.005EU/ml

3. Product Features and Application

Made with borosilicate glass. Cover with aluminum caps. Various size suitable for gel clot reactions, sample dilutions and control standard endotoxin dilutions.

 Catalog No.  

Size mm

(outside diameter)

With

Aluminum Caps

Package

tubes/pack

T087565

Φ8×75

No

65

T107505C

Φ10×75

Yes

5

T107540

 Φ10×75

No

40

T127505C

Φ12×75

Yes

5

T127525

 Φ12×75

No

25

T1310005C

Φ13×100

Yes

5

T1310018

 Φ13×100

No

18

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; pyrogen-free tips; pyrogen-free microplates; endotoxin free sample bottles; 

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the result of endotoxin assay.

 


Product detail pictures:

Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo detail pictures

Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo detail pictures


Related Product Guide:

To be a result of ours specialty and service consciousness, our company has won a superb reputation between customers all around the environment for Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo , The product will supply to all over the world, such as: Hongkong, Israel, Jakarta, We have a good reputation for stable quality products, well received by customers at home and abroad. Our company would be guided by the idea of "Standing in Domestic Markets, Walking into International Markets". We sincerely hope that we could do business with car manufacturers, auto part buyers and the majority of colleagues both at home and abroad. We expect sincere cooperation and common development!
  • Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By Kitty from UAE - 2017.04.08 14:55
    The company account manager has a wealth of industry knowledge and experience, he could provide appropriate program according our needs and speak English fluently.
    5 Stars By Chris from Eindhoven - 2018.09.21 11:44

    Leave Your Messages

    Related products

    • Professional China LAL assay - Rapid Gel Clot 10 Samples Kit – Bioendo

      Professional China LAL assay - Rapid Gel Clot ...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Chinese Professional LAL test kit price - Nymph X Water Purification System – Bioendo

      Chinese Professional LAL test kit price - Nymp...

      NYMPHX Nymph X Water Purification System   Nymph X Water Purification System could transfer tap water into pure water and ultrapure water. Equipped with a pressure stabilizer and low flow-rate operating mode, the system can adapt to various source conditions without any extra pre-treatment necessary. The system also supports multiple water dispensing modes, and the precision of quantitative and quality-controlled dispense of water could reach ±1%. Meanwhile, comprehensive monitoring could be...

    • Low price for Endotoxin Free Tube - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      Low price for Endotoxin Free Tube - Pyrogen-fr...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • New Arrival China limulus lysate - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      New Arrival China limulus lysate - Endotoxin-s...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • OEM China BET Testing - Compact Modular Dry Heat Incubator – Bioendo

      OEM China BET Testing - Compact Modular Dry He...

      Dry Heat Incubator 1. Product description: Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubat...

    • High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo

      High Quality LAL Reagent - Rapid Gel Clot sing...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...