Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo


Product Detail

Related Video

Feedback (2)

To continually enhance the management technique by virtue of your rule of "sincerely, great faith and high-quality are the base of company development", we widely absorb the essence of similar merchandise internationally, and continuously build new merchandise to meet the demands of customers for BET Testing, LAL assay endotoxin, Endotoxin Indicator For Depyrogenation, We have a big inventory to fulfill our customer's requires and needs.
Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo Detail:

Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir

1. Product information

These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog number MPC96 is the pyrogen-free 12 strip X 8 well 96-well plate, strips are individual wrapped.

2. Product parameter

Catalog No.

Description

MP96

Pyrogen-free 96-well Microplate with Lid

MPC96

Pyrogen-free 8 well 96-well Plate Strips, Individual Wrapped

RR5

Pyrogen-free Reagent Resevoir, 5pcs/pack

Endotoxin level: ≤0.0005 EU/well

3. Product feature and application

Endotoxin free microplate and pyrogen-free resevoir mainly used in the kits of end-point chromogenic endotoxin assay, kinetic turbidimetric endotoxin assay and kinetic chromogenic endotoxin assay. Bioendo have launched the micro kinetic chromogenic endotoxin test kit 

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

Why would I use endotoxin-free test consumables?

such as endotoxin free tubes; endotoxin free tips; endotoxin free microplates; endotoxin free sample bottles;

According to China Pharmacopoeia, the utensils needed in the procedure of endotoxin test assay, such as sample vessel, dilution and reaction tubes, pipette tips, have to choose endotoxin free consumables. the utensils needed for the experiment need to be processed to remove possible exogenous endotoxins. If the endotoxin is not removed, it will interfere with the experiment.


Product detail pictures:

Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures

Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo detail pictures


Related Product Guide:

Sticking for the principle of "Super Quality, Satisfactory service" ,We have been striving for being a superb small business partner of you for Quality Inspection for Endotoxin Kits - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo , The product will supply to all over the world, such as: Montreal, Montreal, Mauritius, Company name, is always regarding quality as company' s foundation, seeking for development via high degree of credibility , abiding by ISO quality management standard strictly, creating top-ranking company by spirit of progress-marking honesty and optimism.
  • Customer service staff and sales man are very patience and they all good at English, product's arrival is also very timely, a good supplier.
    5 Stars By Sara from Finland - 2018.12.28 15:18
    Good quality, reasonable prices, rich variety and perfect after-sales service, it's nice!
    5 Stars By Carey from Philippines - 2017.03.28 12:22

    Leave Your Messages

    Related products

    • 2022 High quality LAL assay kit - Kinetic Incubating Microplate Reader ELX808IULALXH  – Bioendo

      2022 High quality LAL assay kit - Kinetic Incu...

      Kinetic Incubating Microplate Reader 1. Product information Kinetic Incubating Microplate Reader Elx808 is a multifunctional kinetic reader designed for bacterial endotoxin assay, fungi (1,3)-ß-D-glucan assay and ELISA assays. The reader is a highly accurate, easy to use instrument for kinetic turbidimetric LAL/TAL assay, kinetic chromogenic LAL test and endpoint chromogenic LAL assay.  Compare to kinetic incubating tube reader,the microplate reader is more efficient and is possible to be sc...

    • Wholesale Price China LAL bacterial endotoxin test - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Wholesale Price China LAL bacterial endotoxin t...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • 2022 China New Design Kinetic chromogenic TAL test - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      2022 China New Design Kinetic chromogenic TAL t...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Reasonable price Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Reasonable price Chromogenic LAL Endotoxin Assa...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 2022 wholesale price endotoxin analysis - Control Standard Endotoxin (CSE) – Bioendo

      2022 wholesale price endotoxin analysis - Cont...

      Control Standard Endotoxin (CSE) 1. Product Information Control Standard Endotoxin (CSE) is extracted from E.coli O111:B4. CSE is an economic alternative to Reference Standard Endotoxin (RSE) in constructing standard curves, validating product and preparing controls in Lyophilized Amebocyte Lysate test. The labeled potency of CSE endotoxinE.coli standard is referenced against RSE. The Control Standard Endotoxin could be used with gel clot assay, kinetic turbidimetric assay or kinetic chromog...

    • PriceList for Kinetic Turbidimetric TAL Kit - Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      PriceList for Kinetic Turbidimetric TAL Kit - ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...