High-quality comes 1st; support is foremost; business is cooperation" is our small business philosophy which is regularly observed and pursued by our organization for Data Logger For Oven Validation, depyrogenation is a 3-log reduction in endotoxin content, endotoxin removal kit, To reward from our strong OEM/ODM capabilities and considerate solutions, remember to speak to us today. We'll sincerely develop and share success with all clientele.
Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo Detail:

Beta-glucans Blocker for Blocking Beta Glucan Pathway

1. Product information

There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Glucan, such as cellulose, using beta-glucans blocker would be a good idea to block the β-1,3-Glucan interference to endotoxin and LAL reagent reaction.

2. Product parameter

Endotoxin level less than 0.005EU/ml

3. Product features and application

Substitute LAL Reagent Water to reconstitute LAL reagent, blocks the beta-glucan mediates factor G pathway and insure the LAL reagent only reacts to endotoxin. For the test samples that has the (1,3)- β-D-Glucan contamination.

Catalog No.

Description

Note

Package

BH10

50mM Tris buffer, pH7.0, 10ml/vial

Used to dilute highly acidic or basic samples.

10 vials/pack

BH50

50mM Tris buffer, pH7.0, 50ml/vial

 Used to dilute highly acidic or basic samples.  10 vials/pack

BY10

10mM Magnesium Buffer, 10ml/vial

Used to overcome chelation effect.

 10 vials/pack

BT10

β-glucans blocker, 10ml/vial

Used to block β-glucan interference in Amebocyte Lysate endotoxin reactions.

 10 vials/pack

PBS50

PBS buffer endotoxin-free, 50ml/vial

Use to wash sample containers, or adjust pH

 10 vials/pack

PBS500

PBS buffer endotoxin-free, 500ml/vial

 

1 vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.


Product detail pictures:

Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures

Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo detail pictures


Related Product Guide:

Well-run equipment, specialist income crew, and better after-sales services; We're also a unified major family, anyone stay with the organization value "unification, determination, tolerance" for Professional Design Bacterial Endotoxin Test Usp Limit - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo , The product will supply to all over the world, such as: UAE, Madrid, Netherlands, They are sturdy modeling and promoting effectively all over the world. Never ever disappearing major functions within a quick time, it's a have to for you of fantastic good quality. Guided by the principle of "Prudence, Efficiency, Union and Innovation. the corporation. ake an excellent efforts to expand its international trade, raise its organization. rofit and raise its export scale. We are confident that we are going to have a bright prospect and to be distributed all over the world in the years to come.
  • The customer service staff is very patient and has a positive and progressive attitude to our interest, so that we can have a comprehensive understanding of the product and finally we reached an agreement, thanks!
    5 Stars By Sally from Vietnam - 2018.12.11 11:26
    Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Johnny from Luxembourg - 2017.02.18 15:54

    Leave Your Messages

    Related products

    • Low price for Bacterial Endotoxin Test Kinetic Turbidimetric Method – Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) – Bioendo

      Low price for Bacterial Endotoxin Test Kinetic ...

      Bioendo KT Endotoxin Test Kit (Kinetic Turbidimetric Assay) 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration. T...

    • Free sample for Bacterial Endotoxin Test Procedure - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Free sample for Bacterial Endotoxin Test Proced...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • OEM/ODM China Dry heat sterilizer validation by ECV - Pyrogen-free Centrifuge Tube – Bioendo

      OEM/ODM China Dry heat sterilizer validation by...

      Pyrogen-free Centrifuge Tube   Product features: * Pyrogen-free Centrifuge tube is made from virgin polypropylene to meet the general requirements of the laboratory. * Pyrogen-free, Endotoxin level <0.005EU/ml * High strength non-toxic materials * Printed clear graduations with marking area * Gamma Radiation Sterilized * 50ml Maximum RCF is 18000g, 15ml Maximum RCF is 12000g * DNase/RNase free * Autoclavable * Temperature range is -20°C to 121°C * Leak-proof * Cap 50% longer ideal for avo...

    • OEM manufacturer BET Testing Method - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM manufacturer BET Testing Method - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • Wholesale Price Endotoxin challenge vial - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Wholesale Price Endotoxin challenge vial - Pyr...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • PriceList for Pyrogen Free Tube - Vortex Mixer – Bioendo

      PriceList for Pyrogen Free Tube - Vortex Mixer...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...