Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo


Product Detail

Related Video

Feedback (2)

Sticking to the principle of "Super High-quality, Satisfactory service" ,We are striving to generally be a very good business partner of you for Bacterial Endotoxin Calculation, Turbidimetric endotoxin assays, Kinetic Turbidimetric Method of endotoxin testing, Please send us your specifications and requirements, or feel free to contact us with any questions or inquiries that you may have.
Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo Detail:

LAL Reagent Water ( Water for Bacterial Endotoxins Test / Water for BET / TAL Reagnt Water ) 

1. Product Information

LAL Reagent Water (Water for Bacterial Endotoxins Test or BET Water or Water for BET is specially processed super-purified endotoxin free water is used for Endotoxin test. Its endotoxin concentration is less than 0.005 EU/ml. Various packages, such as 2ml, 10ml, 50ml, 100ml and 500ml per unit, are provided for users’ convenience. LAL Reagent Water (Water for BET) could be used to dilute the assay sample, construct the stand curve, or reconstitute the Lyophilized Amebocyte Lysate reagents. 

2. Product Parameter

Endotoxin level: ≤0.005 EU/ml

Water for Bacterial Endotoxins Test is specially processed water is used for endotoxin detection. Its endotoxin concentration is less than 0.005EU/ml. We also provide water for BET with endotoxin level less than 0.001EU/ml for the assay sensitivity 0.001 to 5EU/ml kinetic chromogenic assay.

 

3. Product Features and Application

Endotoxin Free Water (Water for BET, LAL Reagent water, Endotoxin free water or BET water) is specially processed water intended for reconstitution of Lyophilized Amebocyte Lysate and Control Standard Endotoxin (CSE), and to dilute samples and control standards in the endotoxin assay operation.

For reconstitution of Lyophilized Amebocyte Lysate or Amebocyte Lysate, dilution of the test samples and Control Standard Endotoxin, preparation endotoxin free buffers, and construction of the standard curve. 500ml BET water main apply in extract endotoxins from medical devices. 

Catalog No.

Volume (ml/vial)

Package

TRW02

2ml in Ampoule

In Ampoule, 10 Ampoules/Pack

TRW05

5ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW10

10ml in Ampoule

 In Ampoule, 10 Ampoules/Pack

TRW50

50ml in Glass Vial

In Glass Vial, 10 Vials/Pack

TRW100

100ml in Glass Vial

 In Glass Vial, 10 Vials/Pack

TRW500

500ml in Glass Bottle

1 Vial

Product Condition

The sensitivity of Lyophilized Amebocyte Lysate and potency of Control Standard Endotoxin are assayed against USP Reference Standard Endotoxin. The Lyophilized Amebocyte Lysate reagent kits come with product instruction, Certificate of Analysis.

What is BET water (bacterial endotoxin test water)?

Bacterial endotoxin test water that is endotoxin free level water, it mainly use for endotoxin test assay in the operation of reconstitution and dilution.

Such as, reconstitute lyophilized lysate reagent, control standard endotoxin dilution reconstitution and dilution, and samples dilutions.

Bioendo BET water (Water for BET) can be named TAL reagent water or LAL reagent water. LAL (lyophilized amebocyte lysate).


Product detail pictures:

Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures

Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo detail pictures


Related Product Guide:

We are committed to providing easy,time-saving and money-saving one-stop purchasing service of consumer for Professional China bacterial endotoxin test - LAL Reagent Water (Water for Bacterial Endotoxins Test) – Bioendo , The product will supply to all over the world, such as: Belgium, Puerto Rico, Slovak Republic, Our products have enjoyed a great reputation for their good quality, competitive prices and prompt shipment in international market. Presently, we are sincerely looking forward to cooperating with more overseas customers based on mutual benefits.
  • The enterprise has a strong capital and competitive power, product is sufficient, reliable, so we have no worries on cooperating with them.
    5 Stars By Anna from Hungary - 2017.06.22 12:49
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Debby from Monaco - 2018.07.12 12:19

    Leave Your Messages

    Related products

    • Reasonable price Chromogenic LAL Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      Reasonable price Chromogenic LAL Endotoxin Assa...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • Best-Selling Endotoxin Lipopolysaccharide - Pyrogen-free (Endotoxin-free) Tris Buffer – Bioendo

      Best-Selling Endotoxin Lipopolysaccharide - Py...

      Pyrogen-free (Endotoxin-free) Tris Buffer 1. Product information Buffers must be validated to be free of detectable endotoxin andinterfering factors. Using 50mM Tris buffer to dissolve or dilute the testsamples is a convenient way to adjust the reaction pH. Pyrogen-free (endotoxin-free) Tris buffer to adjusting the pH of the LAL endotoxin test samples. Lyophilized Amebocyte Lysate testing microbiology detection of endotoxin by horseshoecrab blue blood lysate require certain conditions. The ...

    • Top Suppliers Dry Heat Sterilizer Validation - Single-Channel Mechanical Pipettor – Bioendo

      Top Suppliers Dry Heat Sterilizer Validation -...

      Single-Channel Mechanical Pipettor   1. Product Information Single channel mechanical pipette is ideal tool to support endotoxin detection with Lyophilized Amebocyte Lysate which covers gel-clot technique, kinetic turbidimetric technique, kinetic chromogenic technique, and end-point chromogenic technique. All pipettors are produced by following ISO8655 – 2:2002. The quality control involves gravimetric testing of each pipette with distilled water at 22℃.   2. Product Features: - ...

    • Fast delivery Chromogenic Endotoxin Testing – Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Fast delivery Chromogenic Endotoxin Testing ...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Factory For Bacterial Endotoxin Test Usp Chapter - Pyrogen-free Pipette tips and Consumables – Bioendo

      Factory For Bacterial Endotoxin Test Usp Chapte...

      Pyrogen-free Pipette tips and tip box 1. Product information We offer various low endotoxin, pyrogen-free accessories,includes Water for Bacterial Endotoxins Test, endotoxin-free test tubes, pyrogen-free pipette tips, pyroegn-free microplates for your operation. High quality depyrogenated and low endotoxin level consumables to ensure the success of your endotoxin assays. Pyrogen-free pipette tips are certified to contain <0.001 EU/ml endotoxin. The tips allow more flexibility with diffe...

    • Special Design for Bacterial Endotoxin Test Methods - Endotoxin-free Glass Test Tubes – Bioendo

      Special Design for Bacterial Endotoxin Test Met...

      Endotoxin-free Glass Test Tubes   1. Product Information Endotoxin-free glass test tubes contain less than 0.005EU/ml endotoxin. Catalog number T107505 and T107540  are recommended for use as reaction tubes in gel clot and end-point chromogenic assays. Catalog number T1310018 and T1310005 is recommended for dilution of endotoxin standards and test samples. T1050005C is a special designed short endotoxin reaction tube that allows the pipette tips reaches the tube bottom. T087565 is used ...