OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo


Product Detail

Related Video

Feedback (2)

All we do is always involved with our tenet " Consumer initial, Trust first, devoting within the food stuff packaging and environmental defense for TAL assay kit, Endotoxin Kit, Control Standard Endotoxin Preparation, We warmly welcome all standpoint inquiries from home and abroad to cooperate with us, and anticipate your correspondence.
OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo Detail:

Dry Heat Incubator

1. Product description:

Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

2. Product features

1, LCD display, simple interface.

2, high heating speed, uniformheating, accurate temperature control, high stability, low energy consumptionand no noise.

3, Built in temperature calibrationfunction, automatic fault detection and buzzer alarm function.

4, Built in over-temperatureprotection device, safe and reliable use, prolong the service life of themachine.

5, product design, compact and tight,small occupied space, freer and easier.

6, Various blocks for convenientreplacement, cleaning and disinfection.

7,It Can achieve two independentheating modules, thermostats, unique combo designed to meet the needs of moreexperimental.

dry bath double control, dry incubator doublemodule, limulus polyphemus blue blood, tal kinetic chromogenic method, talendotoxin kit

Product Name & Descriptions

TAL-M2 Dry heat incubator

(single heating module);

One modular total 60 holes for mass test in pharmaceuticals application.

Temperature control Range Ambient+5℃ ~ 150℃
Temperature setting range Ambient+5℃ ~ 150℃
Temperature rising time ≤ 30min (from 20℃ rise to 150℃), rise to 37deg C in about 60s.
Temperature Stability @100~150℃ ≤±1℃
Temperature Stability @40~100℃ ≤±0.5℃
Temperature Uniformity @40℃ ±0.3℃
Modular temperature uniformity ±0.5℃
Displayed Temperature Precision 0.1℃
Temperature Control time 99h59min
Fuse protector 250v, 3A/6A, Φ5×20
Highest Temperature 150℃
Power supply AC220V/AC110V, 50/60Hz, 400W
Dimension D260*W220*H95mm

 


Product detail pictures:

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

With this motto in mind, we've come to be one of quite possibly the most technologically innovative, cost-efficient, and price-competitive manufacturers for OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Georgia, Italy, USA, Insisting over the high-quality generation line management and prospects guide provider, we have made our resolution to offer our shoppers using the initially stage purchasing and soon after provider working experience. Preserving the prevailing helpful relations with our prospects, we even now innovate our product lists the many time to meet up with the brand new wants and stick to the latest trend of this business in Ahmedabad. We're ready to facial area the difficulties and make the transform to grasp many of the possibilities in international trade.
  • We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By April from Mumbai - 2017.01.28 18:53
    This is the first business after our company establish, products and services are very satisfying, we have a good start, we hope to cooperate continuous in the future!
    5 Stars By Heather from Croatia - 2017.03.08 14:45

    Leave Your Messages

    Related products

    • Wholesale Kinetic chromogenic LAL test kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      Wholesale Kinetic chromogenic LAL test kit - E...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Hot sale Kinetic chromogenic LAL Assay kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      Hot sale Kinetic chromogenic LAL Assay kit - E...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Chinese Professional Chromogenic assays - Endpoint Chromogenic Kit EC64405 – Bioendo

      Chinese Professional Chromogenic assays - Endp...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • High Quality Kinetic Chromogenic Endotoxin test kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      High Quality Kinetic Chromogenic Endotoxin test...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Wholesale Kinetic Turbidimetric TAL Test - Kinetic Turbidimetric Amebocyte Lysate Vial – Bioendo

      Wholesale Kinetic Turbidimetric TAL Test - Kin...

      Kinetic Turbidimetric Amebocyte Lysate Vial 1. Product Introduction Kinetic Turbidimetric Amebocyte Lysate Vial is developed based on the principle that the time needed to reach a certain absorbance increase (onset OD), i.e. onset time, is negatively correlated with the endotoxin concentration. Sensitivity could reach 0.005EU/ml, and the detection could reach four orders of magnitude. It is specially suitable for pharmaceuticals industry to monitor endotoxin concentration.  2. Product Parame...

    • High Quality LAL Reagent - Rapid Gel Clot single test kit – Bioendo

      High Quality LAL Reagent - Rapid Gel Clot sing...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...