OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo


Product Detail

Related Video

Feedback (2)

Our company insists all along the quality policy of "product quality is base of enterprise survival; customer satisfaction is the staring point and ending of an enterprise; persistent improvement is eternal pursuit of staff" and the consistent purpose of "reputation first, customer first" for bacterial endotoxin challenge test, endotoxin testing, TAL Reagent, "Quality", "honesty" and "service" is our principle. Our loyalty and commitments remain respectfully at your support. Call Us Today For even further info, get hold of us now.
OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo Detail:

Dry Heat Incubator

1. Product description:

Dry Heat Incubator TAL-M2 is amicroprocessor-controlled device, high precision of temperature control, samplepreparation parallelism, as an alternative to the traditional water bathdevice. It is recommended to use in the gel clot TAL endotoxin assay. And it can be widely used in various other application includes the pharmaceutical, chemical, food safety, environment, quality inspection. TAL-M2 includes 2 heating modules. TAL- M2 A Dry bath incubator Can achieve two independent heating modules, thermostats, unique combo designed to meet the needs of more experimental.

2. Product features

1, LCD display, simple interface.

2, high heating speed, uniformheating, accurate temperature control, high stability, low energy consumptionand no noise.

3, Built in temperature calibrationfunction, automatic fault detection and buzzer alarm function.

4, Built in over-temperatureprotection device, safe and reliable use, prolong the service life of themachine.

5, product design, compact and tight,small occupied space, freer and easier.

6, Various blocks for convenientreplacement, cleaning and disinfection.

7,It Can achieve two independentheating modules, thermostats, unique combo designed to meet the needs of moreexperimental.

dry bath double control, dry incubator doublemodule, limulus polyphemus blue blood, tal kinetic chromogenic method, talendotoxin kit

Product Name & Descriptions

TAL-M2 Dry heat incubator

(single heating module);

One modular total 60 holes for mass test in pharmaceuticals application.

Temperature control Range Ambient+5℃ ~ 150℃
Temperature setting range Ambient+5℃ ~ 150℃
Temperature rising time ≤ 30min (from 20℃ rise to 150℃), rise to 37deg C in about 60s.
Temperature Stability @100~150℃ ≤±1℃
Temperature Stability @40~100℃ ≤±0.5℃
Temperature Uniformity @40℃ ±0.3℃
Modular temperature uniformity ±0.5℃
Displayed Temperature Precision 0.1℃
Temperature Control time 99h59min
Fuse protector 250v, 3A/6A, Φ5×20
Highest Temperature 150℃
Power supply AC220V/AC110V, 50/60Hz, 400W
Dimension D260*W220*H95mm

 


Product detail pictures:

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures

OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo detail pictures


Related Product Guide:

Our personnel are generally in the spirit of "continuous improvement and excellence", and together with the outstanding top quality merchandise, favorable price tag and fantastic after-sales solutions, we try to gain every single customer's rely on for OEM/ODM Factory Application Of LAL Test - Compact Modular Dry Heat Incubator – Bioendo , The product will supply to all over the world, such as: Zambia, Luxemburg, Dubai, we have all day online sales to make sure the pre-sale and after-sale service in time. With all these supports, we can serve every customer with quality product and timely shipping with highly responsibility. Being a young growing company, we might not the best, but we are trying our best to be your good partner.
  • The customer service staff's answer is very meticulous, the most important is that the product quality is very good, and packaged carefully, shipped quickly!
    5 Stars By Tina from Portugal - 2018.11.04 10:32
    The accounts manager made a detailed introduction about the product, so that we have a comprehensive understanding of the product, and ultimately we decided to cooperate.
    5 Stars By Federico Michael Di Marco from Georgia - 2018.03.03 13:09

    Leave Your Messages

    Related products

    • Wholesale Price China LAL test for pyrogens - Rapid Gel Clot single test kit – Bioendo

      Wholesale Price China LAL test for pyrogens - ...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM/ODM Supplier Bacterial Endotoxin Test Kit Suppliers - Pyrogen-free Microplates, pyrogen-free 96-well plates Strips and Reagent Reservoirs – Bioendo

      OEM/ODM Supplier Bacterial Endotoxin Test Kit S...

      Pyrogen-free Microplates, 96 Well Plate Strips and pyrogen free Reagent Reservoir 1. Product information These pyrogen-free 96-well plates (endotoxin-free microplates, pyrogen-free reservoir, cell culture plate, endotoxin-free plates) is used in the End-point Chromogenic Lyophilized Amebocyte Lysate Assay, Kinetic Chromogenic Lyophilized Amebocyte Lysate Assay and Kinetic Turbidimetric  endotoxin test assay. The microplates and resevoirs contain endotoxins <0.005 EU/ml endotoxin. Catalog...

    • OEM/ODM China Kinetic Chromogenic Endotoxin Assay Kit - Endpoint Chromogenic Kit EC64405 – Bioendo

      OEM/ODM China Kinetic Chromogenic Endotoxin Ass...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...

    • 2022 Good Quality TAL assay kit - Vortex Mixer – Bioendo

      2022 Good Quality TAL assay kit - Vortex Mixer...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • 2022 High quality endotoxin detection - Beta-glucans Blocker for Blocking Beta Glucan Pathway – Bioendo

      2022 High quality endotoxin detection - Beta-g...

      Beta-glucans Blocker for Blocking Beta Glucan Pathway 1. Product information There are two pathway in limulus amoebocyte lysate lal reagent, factor C pathway is specific to endotoxin and factor G pathway is specific to(1,3)- β-D-Glucans. If the test sample contains β-1,3-Glucans, the limulus test (Endotoxin test ) will have interferences. β-G-Blocker blocks the reactivity of LAL to β-1,3-Glucans,conferring increased endotoxin specificity to the LAL test. If the test samples containsβ-1,3-Gl...

    • Hot New Products LAL reagent sensitivity - Rapid Gel Clot 10 Samples Kit – Bioendo

      Hot New Products LAL reagent sensitivity - Rap...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...