OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo


Product Detail

Related Video

Feedback (2)

Our goods are commonly recognized and reliable by consumers and may satisfy continually developing economic and social needs for Bioendo, Chromogenic assays, TAL Reagent Water, Adhering to the business principle of mutual benefits, we have won good reputation among our customers because of our perfect services, quality products and competitive prices. We warmly welcome customers from home and abroad to cooperate with us for common success.
OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo Detail:

Endotoxin-specific Lyophilized Amebocyte Lysate

1. Product Information
Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples with potential which are contaminated by ß-Glucan. Bioendo has two Endotoxin-specific Lyophilized Amebocyte Lysate. One is that operator needs to add 0.1ml Water for BET and 0.1ml sample solution to the ampoule of Endotoxin-specific Lyophilized Amebocyte Lysate respectively; the other is that 0.2ml sample solution could be added directly into the ampoule.

2. Product Parameter
Sensitivity range: 0.03, 0.06, 0.125, 0.25, 0.5EU/ml

3. Product Application

Endotoxin-specific Lyophilized Amebocyte Lysate is the optimal choice for endotoxin detection of samples contaminated by beta-glucan such as cellulose, fungi solution.

Note:

Lyophilized Amebocyte Lysate (LAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

ES010030

0.03

ES010060

0.06

ES010125

0.125

ES010250

0.25

ES010500

0.5

Product Condition: 

The sensitivity of Lyophilized Amebocyte Lysate and Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. Lyophilized Amebocyte Lysate kit comes with product instruction, Certificate of Analysis, MSDS. 

Lysate reagent + Matched Control standard endotoxin ( save cost than RSE, CSE vial is calibrated by RSE. )

BET water or called LAL reagent water

Endotoxin free tubes and tips

Above all materials are necessary in the operation of endotoxin test assay.


Product detail pictures:

OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures

OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo detail pictures


Related Product Guide:

We stick to our enterprise spirit of "Quality, Efficiency, Innovation and Integrity". We aim to create more value for our customers with our rich resources, advanced machinery, experienced workers and excellent services for OEM/ODM China limulus amoebocyte lysate LAL test - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo , The product will supply to all over the world, such as: Roman, Slovak Republic, Argentina, Actually need to any of those objects be of interest to you, make sure you allow us to know. We'll be delighted to present you a quotation on receipt of one's comprehensive specs. We've our individual specialist R&D enginners to meet any of the requriements, We look forward to receiving your enquires soon and hope to have the chance to work together with you inside the future. Welcome to take a look at our organization.
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Cindy from Albania - 2017.09.30 16:36
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Linda from Lithuania - 2018.10.31 10:02

    Leave Your Messages

    Related products

    • Factory Supply Kinetic chromogenic LAL Assay kit - Micro Kinetic Chromogenic Endotoxin Assay Kit – Bioendo

      Factory Supply Kinetic chromogenic LAL Assay ki...

       Micro KC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay) The Bioendo MicroKC Endotoxin Test Kit (Micro Kinetic Chromogenic Endotoxin Assay), which adopts the micro-technical kinetic chromogenic method, is equipped with a special customized 96-well microplates, which can be used in the endotoxin test of microbial detection system Elx808IULALXH and other conventional endotoxin detection equipment to realize the micro-kinetic chromogenic endotoxin detection. The micro KC kit mee...

    • Factory Cheap Hot limulus amebocyte lysate kit - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Factory Cheap Hot limulus amebocyte lysate kit ...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Manufacturing Companies for Advantages Of LAL Test - Vortex Mixer – Bioendo

      Manufacturing Companies for Advantages Of LAL T...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Hot New Products Kinetic chromogenic TAL test kit - Endpoint Chromogenic Kit EC80545 – Bioendo

      Hot New Products Kinetic chromogenic TAL test k...

      Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) 1. Product Information Bioendo EC Endotoxin Test Kit (End-point Chromogenic Assay, Diazo Coupling) provides a fast measurement for endotoxin quantification. The endotoxin in the sample activates a cascade of enzymes in Amebocyte Lysate, the activated enzyme splits the synthetic substrate, releasing a yellow-colored item. Then the yellow item can further react with diazo reagents to form purple items with maximum abso...

    • Factory Free sample Coagulation Gel - Vortex Mixer – Bioendo

      Factory Free sample Coagulation Gel - Vortex M...

      Vortex mixer 1. Product information The Vortex mixer widely used in life science, physical and chemicalanalysis fields, for vigorous re-suspension of cells or chemical pelletsin tubes up to 15 ml. It is good for the dilution and mixing the Control Standard Endotoxin solution in endotoxin assay with gel clot method, kinetic chromogenic method, kinetic turbidimetric method and end-point chromogenic method. 2. Features - Touch and continuous operations - with wide speed range of 0-2500rpm,st...

    • Factory Cheap Hot LAL chromogenic detection - Endpoint Chromogenic Kit EC64405 – Bioendo

      Factory Cheap Hot LAL chromogenic detection - ...

      End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) 1. Product Information End-point Chromogenic Endotoxin Test Kit (without Diazo Coupling) is conducted by adding a colorless artificial peptide substrate solution into mixture of Lyophilized Amebocyte Lysate and test sample after a certain incubation period. If test sample contain endotoxin, a yellow color will develop in the 96 well microplate. Its absorbance (λmax = 405nm) is related to the endotoxin concentration. Endotoxin ...