OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo


Product Detail

Related Video

Feedback (2)

Our advantages are lower prices,dynamic sales team,specialized QC,strong factories,high quality products and services for Bacteria Producing Endotoxin, LAL reagent manufacturer, Bacterial Endotoxin Calculation, We believe that in good quality more than quantity. Before export of the hair there is strict top quality control check during treatment as per international good quality standards.
OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo Detail:

Bioendo GC Endotoxin Test Kit

Bioendo GC Endotoxin Test Kit (Gel Clot Assay) 

1. Product Information

Bioendo GC Endotoxin Test Kit (Gel Clot Assay) contains 128 Tests/Kit, 400Tests/Kit, 1600Tests/Kit, and 4500 Tests/Kit. And sensitivity of Amebocyte Lysate included by the Kit is 0.03 EU/ml, 0.06 EU/ml, 0.125 EU/ml, 0.25 EU/ml, 0.5 EU/ml. The Kit contains Amebocyte Lysate, CSE and Water for BET. Four kinds of configuration of gel-clot endotoxin assay kit to satisfied the demand. This means you could choose different configuration kits according to the requirement. 

2. Product Parameter 

Sensitivities: 0.03EU/ml, 0.06EU/ml, 0.125EU/ml, 0.25EU/ml, 0.5 EU/ml

3.Product Feature and Application

Full range of sensitivities to meet the demand. No special instrument is needed for endotoxin detection with Bioendo GC Endotoxin Test Kit (Gel Clot Assay). It is the best choice when you need to do lots of endotoxin detection.

Note:

Lyophilized Amebocyte Lysate (LAL/TAL) reagent manufactured by Bioendo is made from amebocyte lysate derived blood of horseshoe crab.

Catalog No.

Sensitivity (EU/ml)

Description

Kit Contents

GC90520030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

4500 Tests/Kit

90 Gel Clot Lyophilized Amebocyte Lysate,

5.2ml (50 Tests/Vial);

20 CSE10V;

GC90520060

0.06

GC90520125

0.125

GC90520250

0.25

GC90520500

0.5

GC08520030

0.03

Bioendo™ GC Endotoxin

Test Kit (Gel Clot Assay)

400 Tests/Kit

8 Gel Clot Lyophilized Amebocyte Lysate,

5.2ml (50 Tests/Vial);

4 CSE10V;

2 Water for BET, 50ml/vial;

GC08520060

0.06

GC08520125

0.125

GC08520250

0.25

GC08520500

0.5

GC100170030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

1600 Tests/Kit

100 Gel Clot Lyophilized Amebocyte Lysate, 1.7ml (16 Tests/Vial);

10 CSE10V;

GC100170060

0.06

GC100170125

0.125

GC100170250

0.25

GC100170500

0.5

GC08170030

0.03

Bioendo™ GC Endotoxin Test Kit (Gel Clot Assay)

128 Tests/Kit

8 Gel Clot Lyophilized Amebocyte Lysate,

1.7ml (16 Tests/Vial);

4 CSE10V;

2 Water for BET, 50ml/vial;

GC08170060

0.06

GC08170125

0.125

GC08170250

0.25

GC08170500

0.5

Product condition:

Endotoxin Test kit’s sensitivity and the Control Standard Endotoxin potency are assayed against USP Reference Standard Endotoxin. The Endotoxin Test reagentkits come with product instruction, Certificate of Analysis.


Product detail pictures:

OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures

OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures

OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo detail pictures


Related Product Guide:

Our firm sticks on the theory of "Quality will be the life in the enterprise, and status could be the soul of it" for OEM/ODM China Bacterial Endotoxin Test Gel Clot Method Sop - Bioendo GC Endotoxin Test Kit (Gel Clot Assay) – Bioendo , The product will supply to all over the world, such as: Argentina, Brasilia, Holland, To meet the requirements of specific customers for each bit more perfect service and stable quality merchandise. We warmly welcome customers around the world to visit us, with our multi-faceted cooperation, and jointly develop new markets, create a brilliant future!
  • We have been cooperated with this company for many years, the company always ensure timely delivery ,good quality and correct number, we are good partners.
    5 Stars By Zoe from Croatia - 2017.08.15 12:36
    We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Prima from Guyana - 2018.05.13 17:00

    Leave Your Messages

    Related products

    • High reputation 1000ul Pipette tip box - Single-Channel Mechanical Pipettes (Semi-sterile) – Bioendo

      High reputation 1000ul Pipette tip box - Singl...

      Single-Channel Mechanical Pipettes (Semi-sterile)   1. Product Information The Single-Channel Mechanical Pipettes (Semi-sterile) is adjustable, which could be used to dispense liquid precisely. Measuring volume of our Single-Channel Mechanical Pipettes (Semi-sterile) ranges from 0.1μL to 5mL. Products are produced based on ISO8655/DIN12650. It could be widely employed on endotoxin detection, etc..   2. Product Features - Light weight, economic - The pipettes cover volume range from 0.1μL to 5...

    • Manufactur standard Endotossine LAL Test - Rapid Gel Clot single test kit – Bioendo

      Manufactur standard Endotossine LAL Test - Rap...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • OEM manufacturer BET Testing Method - Rapid Gel Clot 10 Samples Kit – Bioendo

      OEM manufacturer BET Testing Method - Rapid Ge...

      Rapid Gel Clot Endotoxin Assay Kit (10 Samples Kit) 1. Product Information Bioendo Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, RG kit’s result could be gained within 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need the multi steps’ dilution of Control Standard Endotoxin and test samples. Operation procedure...

    • OEM/ODM Supplier Kit LAL - Rapid Gel Clot single test kit – Bioendo

      OEM/ODM Supplier Kit LAL - Rapid Gel Clot sing...

      Rapid Gel Clot Endotoxin Test Kit (Single Sample Test Kit) 1. Product Information Rapid Gel Clot Endotoxin Assay Kit is designed to rapidly quantify endotoxin in water or dialysate. Generally, read the result in about 30 minutes. Under the guidance of detecting endotoxin in water or dialysate quickly, endotoxin detection with Bioendo Rapid Gel Clot Endotoxin Assay Kit does not need to multi steps’ dilution of Control Standard Endotoxin and test samples. Easy and convenient procedures ...

    • Best quality limulus lysate assay - Endotoxin-specific Lyophilized Amebocyte Lysate – Bioendo

      Best quality limulus lysate assay - Endotoxin-...

      Endotoxin-specific Lyophilized Amebocyte Lysate 1. Product Information Lyophilized Amebocyte Lysate extracted from horseshoe crab contains factor C pathway which reacts to endotoxin and factor G pathway which reacts to (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate contains ß-Glucan inhibitor, which will avoid false positive, result happening between factor C pathway and (1,3)- ß-D-Glucan. Endotoxin-specific Lyophilized Amebocyte Lysate is especially suitable for samples ...

    • Manufactur standard Endotoxin Lps - Endotoxin Challenge Vials (Endotoxin Indicator) – Bioendo

      Manufactur standard Endotoxin Lps - Endotoxin ...

       Endotoxin Challenge Vials (Endotoxin Indicator)   1. Product Information The Endotoxin Challenge Vial (ECV,Endotoxin Indicator) is used in the validation of dry heat depyrogenation cycles. Endotoxin Challenge Vials are placed in the cold spots of the dry heat oven. After cycle completion, the log reduction in endotoxin levels can be determined by comparing the endotoxin levels in the baked vs not baked Endotoxin Indicators. The Endotoxin Challenge vials are designed to indicate a minimum 3...